100 A Fuses 389

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

FWH-100B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 A

Tab/Blade

475 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.947 in (24.05 mm)

0.947 x 1.736 in (24.05 x 44.09 mm)

1.736 in (44.09 mm)

CE; CSA; UL

FWP-100A22FI

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

100 A

End Cap

1.1 kJ

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.874 in (22.2 mm)

Indicator

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

CE; IEC; UL

OSD100

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

100 A

Tab/Blade

25 kJ

80 kA

Box

0.827 in (21 mm)

0.827 x 2.146 in (21 x 54.5 mm)

2.146 in (54.5 mm)

IEC

TCF100

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

-40 °C (-40 °F)

Tin

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

2.992 in (76 mm)

0.984 in (25 mm)

e3

Indicator

3.01 x 1 x 1.26 in (76.45 x 25.4 x 32 mm)

1.26 in (32 mm)

CSA; UL

80 °C (176 °F)

Time Delay

4998100.M-M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

100 A

Tab/Blade

18.3 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.323 in (8.2 mm)

UL

125 °C (257 °F)

JTD100

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

68.15 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

2.626 in (66.7 mm)

CSA; UL

Time Delay

EV1K100.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

100 A

Tab/Blade

2.67 kJ

-40 °C (-40 °F)

30 kA

Bulk

1 in (25.4 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

157.5701.6101

Littelfuse

Electric Fuse

Inline/Holder

48 V

100 A

Tab/Blade

-40 °C (-40 °F)

600 A

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

3298100.Z

Littelfuse

Electric Fuse

Surface Mount

32 V

100 A

Wraparound

31 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.181 in (30 mm)

1.047 in (26.6 mm)

Mega

0.63 in (16 mm)

125 °C (257 °F)

SPFJ100.X

Littelfuse

Electric Fuse

Inline/Holder

1 KV

100 A

Tab/Blade

12.244 kJ

20 kA

8 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL

0JTD100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

68.15 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

600 V

2.626 in (66.7 mm)

CSA; UL

Time Delay

142.5631.6102

Littelfuse

Electric Fuse

Inline/Holder

58 V

100 A

Tab/Blade

42.5 kJ

-40 °C (-40 °F)

Matte Tin

1 kA

42500

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.472 x 0.307 x 0.63 in (12 x 7.8 x 16 mm)

0.307 in (7.8 mm)

UL

125 °C (257 °F)

PSR070FS0100Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

100 A

Threaded

974 J

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.913 in (74 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

C22G100

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 A

End Cap

120 kA

0.866 in (22 mm)

500 V

0.866 x 2.283 in (22 x 58 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

C22M100

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

100 A

End Cap

120 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

0CNN100E.V

Littelfuse

Electric Fuse

Inline/Holder

80 V

100 A

Tab/Blade

2.7 kA

3.181 in (80.8 mm)

80 V

3.18 in (80.77 mm)

CUL; UL

Very Fast

0JTD100.VXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

68.15 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

600 V

Indicator

2.626 in (66.7 mm)

CSA; UL

Time Delay

0TLS100.TXV

Littelfuse

Electric Fuse

Inline/Holder

170 V

100 A

Tab/Blade

Silver

100 kA

Bulk

0.563 in (14.3 mm)

e4

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

170M1567

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

100 A

Tab/Blade

695 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.378 in (54 x 21 x 35 mm)

1.378 in (35 mm)

CE; DIN 43620; IEC; UL

EV20-100

Eaton Corporation

Electric Fuse

100 A

Tab/Blade

20 kA

1470

0.787 in (20 mm)

0.787 x 1.575 in (20 x 40 mm)

1.575 in (40 mm)

CE

Fast

JTD100ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

68.15 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

Indicator

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CSA; UL

Time Delay

PF-FB1-100

Bourns

Electric Fuse

Inline/Holder

800 V

800 V

100 A

Tab/Blade

3.1 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 800 VDC: 50000 A

Bulk

0.949 in (24.1 mm)

2.717 in (69 mm)

CUL; UL

125 °C (257 °F)

PV-100A-01XL-B-15

Eaton Corporation

Electric Fuse

Inline/Holder

1.5 KV

100 A

Tab/Blade

1.1 kJ

30 kA

Bulk

5.157 in (131 mm)

1.772 in (45 mm)

Indicator

2.362 in (60 mm)

IEC; UL

PV-100ANH1

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

100 A

Tab/Blade

1.3 kJ

50 kA

1300

Bulk

2.953 in (75 mm)

1.575 in (40 mm)

1 KV

2.953 x 1.575 x 2.087 in (75 x 40 x 53 mm)

2.087 in (53 mm)

CSA; IEC; UL

0998100.UX-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

100 A

Tab/Blade

24 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

170M3691

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

1.3 KV

100 A

Tab/Blade

750 J

100 kA

Rated Breaking Capacity at 1300 VDC: 100000 A

Box

6.142 in (156 mm)

1.772 in (45 mm)

Indicator

6.142 x 1.772 x 1.772 in (156 x 45 x 45 mm)

1.772 in (45 mm)

CE; IEC; UL

FBP-100

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

100 A

Tab/Blade

200 kA

1.063 in (27 mm)

1.063 x 2.126 in (27 x 54 mm)

2.126 in (54 mm)

UL

153.0020.6102

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

42.5 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

0283100.MXJ

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

-40 °C (-40 °F)

40 ms

1.874 in (47.6 mm)

0.593 in (15.05 mm)

32 V

0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm)

0.846 in (21.5 mm)

125 °C (257 °F)

IDSR100ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

SPNH0100.XXDEMS

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

100 A

Tab/Blade

10 kJ

30 kA

Bulk

5.165 in (131.2 mm)

2.008 in (51 mm)

NH

2.008 in (51 mm)

UL

KLC100

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

-55 °C (-67 °F)

200 kA

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

125 °C (257 °F)

Very Fast

KLA100

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

100 A

Tab/Blade

100 kA

KLA

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

JLLN100P

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

2.157 in (54.8 mm)

CE; CSA; CUL; UL

Fast

CCK100

Littelfuse

Electric Fuse

Inline/Holder

125 V

100 A

Tab/Blade

10 kA

1.06 in (26.92 mm)

1 x 3.454 in (25.4 x 87.73 mm)

4.46 in (113.28 mm)

Time Delay

LCN100E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

60 kA

LCN

6.38 in (162.05 mm)

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

NH00CM100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

153.0010.6102

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

42.5 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

KLNR100

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

100 A

Tab/Blade

200 kA

KLNR

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

5.874 in (149.2 mm)

CSA; UL

Fast

0298100.UXP-1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

27.6 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

L50S100

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1 in (25.4 mm)

1 x 2.126 in (25.4 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

298100

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

31.1 kJ

-40 °C (-40 °F)

2 kA

Rated Breaking Capacity at 32 VDC: 2000 A

31100

1.15 in (29.21 mm)

0.75 in (19.05 mm)

32 V

562 μΩ

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

Slow

100-3R-1C-5.5W

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

100 A

End Cap

250 A

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

LVSP100-L

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

160.747 kJ

200 kA

1 in (25.4 mm)

2.62 in (66.55 mm)

UL

TLS-V100

Littelfuse

Electric Fuse

Inline/Holder

170 V

100 A

Tab/Blade

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 1.26 in (14.3 x 32.004 mm)

1.26 in (32.004 mm)

UL

0298100.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

31.1 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

LA70QS100-22FI

Littelfuse

Electric Fuse

Inline/Holder

690 V

700 V

100 A

End Cap

8 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

CSA; UL

Very Fast

100E1C15.5

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 18.875 in (76.2 x 479.43 mm)

18.875 in (479.43 mm)

Medium

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.