Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
Tab/Blade |
475 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.947 in (24.05 mm) |
0.947 x 1.736 in (24.05 x 44.09 mm) |
1.736 in (44.09 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
100 A |
End Cap |
1.1 kJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.874 in (22.2 mm) |
Indicator |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
100 A |
Tab/Blade |
25 kJ |
80 kA |
Box |
0.827 in (21 mm) |
0.827 x 2.146 in (21 x 54.5 mm) |
2.146 in (54.5 mm) |
IEC |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
2.992 in (76 mm) |
0.984 in (25 mm) |
e3 |
Indicator |
3.01 x 1 x 1.26 in (76.45 x 25.4 x 32 mm) |
1.26 in (32 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
18.3 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
68.15 kJ |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.126 in (28.6 mm) |
2.626 in (66.7 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
2.67 kJ |
-40 °C (-40 °F) |
30 kA |
Bulk |
1 in (25.4 mm) |
2.875 in (73.03 mm) |
125 °C (257 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
600 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
100 A |
Wraparound |
31 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.181 in (30 mm) |
1.047 in (26.6 mm) |
Mega |
0.63 in (16 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
12.244 kJ |
20 kA |
8 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
68.15 kJ |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.126 in (28.6 mm) |
600 V |
2.626 in (66.7 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
100 A |
Tab/Blade |
42.5 kJ |
-40 °C (-40 °F) |
Matte Tin |
1 kA |
42500 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
58 V |
0.472 x 0.307 x 0.63 in (12 x 7.8 x 16 mm) |
0.307 in (7.8 mm) |
UL |
125 °C (257 °F) |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
100 A |
Threaded |
974 J |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
End Cap |
120 kA |
0.866 in (22 mm) |
500 V |
0.866 x 2.283 in (22 x 58 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
End Cap |
120 kA |
C22 |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
80 V |
100 A |
Tab/Blade |
2.7 kA |
3.181 in (80.8 mm) |
80 V |
3.18 in (80.77 mm) |
CUL; UL |
Very Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
68.15 kJ |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.126 in (28.6 mm) |
600 V |
Indicator |
2.626 in (66.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
Silver |
100 kA |
Bulk |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
690 V |
100 A |
Tab/Blade |
695 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
Indicator |
2.126 x 0.827 x 1.378 in (54 x 21 x 35 mm) |
1.378 in (35 mm) |
CE; DIN 43620; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
100 A |
Tab/Blade |
20 kA |
1470 |
0.787 in (20 mm) |
0.787 x 1.575 in (20 x 40 mm) |
1.575 in (40 mm) |
CE |
Fast |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
68.15 kJ |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.126 in (28.6 mm) |
Indicator |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
800 V |
800 V |
100 A |
Tab/Blade |
3.1 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 800 VDC: 50000 A |
Bulk |
0.949 in (24.1 mm) |
2.717 in (69 mm) |
CUL; UL |
125 °C (257 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.5 KV |
100 A |
Tab/Blade |
1.1 kJ |
30 kA |
Bulk |
5.157 in (131 mm) |
1.772 in (45 mm) |
Indicator |
2.362 in (60 mm) |
IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
1.3 kJ |
50 kA |
1300 |
Bulk |
2.953 in (75 mm) |
1.575 in (40 mm) |
1 KV |
2.953 x 1.575 x 2.087 in (75 x 40 x 53 mm) |
2.087 in (53 mm) |
CSA; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
24 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.3 KV |
100 A |
Tab/Blade |
750 J |
100 kA |
Rated Breaking Capacity at 1300 VDC: 100000 A |
Box |
6.142 in (156 mm) |
1.772 in (45 mm) |
Indicator |
6.142 x 1.772 x 1.772 in (156 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; IEC; UL |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
100 A |
Tab/Blade |
200 kA |
1.063 in (27 mm) |
1.063 x 2.126 in (27 x 54 mm) |
2.126 in (54 mm) |
UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
42.5 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
40 ms |
1.874 in (47.6 mm) |
0.593 in (15.05 mm) |
32 V |
0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm) |
0.846 in (21.5 mm) |
125 °C (257 °F) |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
100 A |
200 kA |
IDSR |
Rated Breaking Capacity at 600 VDC: 20000 A |
Indicator |
CSA; UL |
Time Delay |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
100 A |
Tab/Blade |
10 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
-55 °C (-67 °F) |
200 kA |
1 in (25.4 mm) |
1 x 2.874 in (25.4 x 73 mm) |
2.874 in (73 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
100 A |
Tab/Blade |
100 kA |
KLA |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
0.811 in (20.6 mm) |
2.157 in (54.8 mm) |
CE; CSA; CUL; UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
100 A |
Tab/Blade |
10 kA |
1.06 in (26.92 mm) |
1 x 3.454 in (25.4 x 87.73 mm) |
4.46 in (113.28 mm) |
Time Delay |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
100 A |
End Cap |
60 kA |
LCN |
6.38 in (162.05 mm) |
6.38 x 23.875 in (162.05 x 606.43 mm) |
23.875 in (606.43 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
100 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.02 in (51.3 mm) |
0.787 in (20 mm) |
Indicator |
2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm) |
2.126 in (54 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
42.5 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
100 A |
Tab/Blade |
200 kA |
KLNR |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.063 in (27 mm) |
5.874 in (149.2 mm) |
CSA; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
27.6 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.75 in (19.05 mm) |
e3 |
32 V |
Mega |
0.381 in (9.69 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
450 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 450 VDC: 20000 A |
1 in (25.4 mm) |
1 x 2.126 in (25.4 x 54 mm) |
2.126 in (54 mm) |
CSA; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
Rated Breaking Capacity at 32 VDC: 2000 A |
31100 |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
32 V |
562 μΩ |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
Slow |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
250 A |
Part Number With Hookeye Attachment |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
160.747 kJ |
200 kA |
1 in (25.4 mm) |
2.62 in (66.55 mm) |
UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
Silver |
Rated Breaking Capacity at 170 VDC: 100000 |
0.563 in (14.3 mm) |
e4 |
0.563 x 1.26 in (14.3 x 32.004 mm) |
1.26 in (32.004 mm) |
UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
690 V |
700 V |
100 A |
End Cap |
8 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
CSA; UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
100 A |
End Cap |
80 kA |
5 m |
3 in (76.2 mm) |
Striker |
3 x 18.875 in (76.2 x 479.43 mm) |
18.875 in (479.43 mm) |
Medium |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.