Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
100 A |
End Cap |
225 A |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
100 A |
End Cap |
80 kA |
LDZ |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
100 A |
Tab/Blade |
200 kA |
Bulk |
1 in (25.4 mm) |
1 x 2.626 in (25.4 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; QPL; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
100 A |
Tab/Blade |
3.54 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
24 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
Mega |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
250 A |
15 s |
3 in (76.2 mm) |
Striker |
3 x 15.875 in (76.2 x 403.23 mm) |
15.874 in (403.2 mm) |
40 °C (104 °F) |
Medium |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
100 A |
Tab/Blade |
10 kA |
1.06 in (26.92 mm) |
4.46 in (113.28 mm) |
Time Delay |
||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
300 V |
100 A |
Tab/Blade |
4.1 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.22 in (31 mm) |
1.22 x 1.63 in (31 x 41.4 mm) |
1.63 in (41.4 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
27.6 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
1.15 in (29.2 mm) |
0.75 in (19.05 mm) |
e3 |
32 V |
Mega |
0.381 in (9.69 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
Tab/Blade |
80 kA |
4.75 in (120.65 mm) |
4.75 x 15.13 in (120.65 x 384.3 mm) |
15.13 in (384.3 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
18.3 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
100 A |
End Cap |
60 kA |
15GSE-100E |
3 in (76.2 mm) |
3 x 21.874 in (76.2 x 555.6 mm) |
21.874 in (555.6 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
31.1 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Pin Wire |
-40 °C (-40 °F) |
300 ms |
2.394 in (60.8 mm) |
0.72 in (18.3 mm) |
2.394 x 0.72 x 0.661 in (60.8 x 18.3 x 16.8 mm) |
0.661 in (16.8 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
100 A |
-40 °C (-40 °F) |
0.898 in (22.8 mm) |
0.638 in (16.2 mm) |
32 V |
0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm) |
0.846 in (21.5 mm) |
125 °C (257 °F) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
600 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
100 A |
Tab/Blade |
250 A |
Rated Breaking Capacity=250A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 13 in (76.2 x 330.2 mm) |
13 in (330.2 mm) |
Medium |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
100 A |
Tab/Blade |
42.5 kJ |
-40 °C (-40 °F) |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.307 in (7.8 mm) |
UL |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
100 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
2.43 in (61.72 mm) |
UL |
Fast |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
25.8 KV |
100 A |
End Cap |
40 kA |
5 m |
6.382 in (162.1 mm) |
Striker |
6.38 x 24.625 in (162.05 x 625.48 mm) |
24.875 in (631.83 mm) |
Medium |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
80 kA |
5 m |
3 in (76.2 mm) |
Striker |
3 x 15.875 in (76.2 x 403.23 mm) |
15.874 in (403.2 mm) |
Medium |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
End Cap |
200 kA |
LGD |
Rated Breaking Capacity at 300 VDC: 20000 A |
CSA; IEC; UL |
Time Delay |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
23 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
58 V |
100 A |
Wraparound |
14 kJ |
-40 °C (-40 °F) |
Matte Tin |
2 kA |
1900 |
0.925 in (23.5 mm) |
0.787 in (20 mm) |
e3 |
58 V |
0.925 x 0.787 x 0.453 in (23.5 x 20 x 11.5 mm) |
0.453 in (11.5 mm) |
UL |
125 °C (257 °F) |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
100 A |
End Cap |
60 kA |
100E-1C-15.5 |
3 in (76.2 mm) |
3 x 18.874 in (76.2 x 479.4 mm) |
18.874 in (479.4 mm) |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
100 A |
End Cap |
60 kA |
LCN |
3 in (76.2 mm) |
3 x 23.875 in (76.2 x 606.43 mm) |
23.875 in (606.43 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
100 V |
100 A |
Tab/Blade |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 100 VDC: 20000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
1.311 x 7.874 in (33.3 x 200 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
100 kA |
Bulk |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
100 A |
End Cap |
80 kA |
LCZ |
3 in (76.2 mm) |
3 x 17.87 in (76.2 x 453.89 mm) |
17.87 in (453.89 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
23 kJ |
-40 °C (-40 °F) |
2.5 kA |
100 ms |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
36 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
625 A |
1 m |
Bulk |
1.614 in (41 mm) |
0.433 in (11 mm) |
0.028 in (0.7 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
80 V |
100 A |
Tab/Blade |
2.7 kA |
3.181 in (80.8 mm) |
3.18 in (80.77 mm) |
CUL; UL |
Very Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
750 V |
100 A |
Tab/Blade |
18 J |
100 kA |
Rated Breaking Capacity at 750 VDC: 100000 A |
1.22 in (31 mm) |
1.22 x 6.811 in (31 x 173 mm) |
6.811 in (173 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
24 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
100 A |
Tab/Blade |
830 mJ |
100 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 2.854 in (40 x 40 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
100 A |
Tab/Blade |
Silver |
100 kA |
Bulk |
0.563 in (14.3 mm) |
e4 |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
140 kJ |
169 |
Rated Breaking Capacity at 32 VDC: 1000 A |
1.169 in (29.7 mm) |
0.358 in (9.1 mm) |
1.169 x 0.358 x 0.839 in (29.7 x 9.1 x 21.3 mm) |
0.839 in (21.3 mm) |
UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
250 A |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
24 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
100 A |
Tab/Blade |
24 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm) |
0.327 in (8.3 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
100 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
100 A |
End Cap |
250 A |
Part Number With Hookeye Attachment |
3 in (76.2 mm) |
3 x 17.875 in (76.2 x 454.03 mm) |
17.875 in (454.03 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
Tab/Blade |
4.4 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
1 in (25.4 mm) |
500 V |
1 x 2.13 in (25.4 x 54.1 mm) |
2.13 in (54.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
100 A |
Tab/Blade |
250 A |
Rated Breaking Capacity=250A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 13 in (76.2 x 330.2 mm) |
13 in (330.2 mm) |
Medium |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.