100 A Fuses 389

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LA30QS100-4TI

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

100 A

Tab/Blade

4.1 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

Indicator

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

CNN100

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

100 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

125 V

3.178 x 2.43 in (80.72 x 61.72 mm)

UL

Very Fast

CY22X58M100

Littelfuse

Electric Fuse

Inline/Holder

500 V

100 A

End Cap

120 kA

0.866 in (22 mm)

500 V

0.866 x 2.283 in (22 x 58 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

Time Lag

0298100ZXH

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

31.1 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

PAL4100

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Bulk

100E2C15.5

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

80 kA

5 m

6.382 in (162.1 mm)

Striker

6.38 x 18.875 in (162.05 x 479.43 mm)

18.875 in (479.43 mm)

Medium

0294100.MXJ

Littelfuse

Electric Fuse

100 A

-40 °C (-40 °F)

0.906 in (23 mm)

0.646 in (16.4 mm)

32 V

0.906 x 0.646 x 0.996 in (23 x 16.4 x 25.3 mm)

0.996 in (25.3 mm)

125 °C (257 °F)

0CNL100.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

100 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

UL

Fast

153.5395.6102

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

46.8 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.142 in (29 mm)

0.642 in (16.3 mm)

32 V

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

LCU100E

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

100 A

End Cap

80 kA

LCU

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

142.7020.6002

Littelfuse

Electric Fuse

100 A

-40 °C (-40 °F)

Tin

1 kA

42500

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

0283100.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

100 A

Tab/Blade

-40 °C (-40 °F)

40 ms

1.874 in (47.6 mm)

0.593 in (15.05 mm)

32 V

0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm)

0.846 in (21.5 mm)

125 °C (257 °F)

07945825300

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

100 A

Tab/Blade

974 J

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

0JLS100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

200 kA

Bulk

1 in (25.4 mm)

2.626 in (66.7 mm)

CE; CSA; QPL; UL

Fast

PSR030UL0100

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

100 A

Tab/Blade

437 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR070UL0100

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

100 A

Tab/Blade

974 J

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR030US0100

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

100 A

Tab/Blade

437 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

1.929 in (49 mm)

CUL; UL

125 °C (257 °F)

Fast

FLNR100.VXID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

1.031 in (26.2 mm)

Indicator

5.874 in (149.2 mm)

CSA; UL

Time Delay

FLNR100.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

1.031 in (26.2 mm)

5.874 in (149.2 mm)

CSA; UL

Time Delay

EV1K100

Littelfuse

Electric Fuse

Inline/Holder

1 KV

100 A

Tab/Blade

2.67 kJ

-40 °C (-40 °F)

30 kA

Bulk

1 in (25.4 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

0PAL1100XP

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Blister

0PAL2100XPA

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Blister

0RLN100.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 A

Tab/Blade

10 kA

1.063 in (27 mm)

5.874 in (149.2 mm)

CE; CSA; UL

L60S100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

1.063 in (27 mm)

2.906 in (73.8 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0PAL2100X

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Bulk

0NLN100.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

100 A

Tab/Blade

50 kJ

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

1.063 in (27 mm)

Indicator

5.874 in (149.2 mm)

CE; CSA; UL

0RLS100.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

10 kA

1.311 in (33.3 mm)

7.874 in (200 mm)

CE; CSA; UL

0PAL4100XP

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Blister

KLSR0100

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

7.874 in (200 mm)

CE; CSA; UL

Fast

0PAL1100X

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Bulk

KLNR0100

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

5.874 in (149.2 mm)

CE; CSA; UL

Fast

0PAL1100XPA

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Blister

LLSRK100.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

7.874 in (200 mm)

CE; CSA; UL; QPL

Time Delay

0PAL4100X

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Bulk

LLNRK100.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

5.874 in (149.2 mm)

CE; CSA; UL; QPL

Time Delay

0NLS100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 A

Tab/Blade

158 kJ

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

7.874 in (200 mm)

CSA; UL

0PAL2100XP

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Blister

0PAL4100XPA

Littelfuse

Electric Fuse

Inline/Holder

100 A

Tab/Blade

Blister

0JTD100.VID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

68.15 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.126 in (28.6 mm)

Indicator

2.626 in (66.7 mm)

CSA; UL

Time Delay

0KLC100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

1 in (25.4 mm)

2.874 in (73 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L70QS100

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

100 A

Tab/Blade

966 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

1 in (25.4 mm)

2.875 in (73.03 mm)

CUL; UL

125 °C (257 °F)

Very Fast

PSR030DS0100Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

100 A

Tab/Blade

437 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR070DL0100Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

100 A

Tab/Blade

974 J

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.823 in (71.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR030DL0100Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

100 A

Tab/Blade

437 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

0TLS100.TXLSE

Littelfuse

Electric Fuse

Inline/Holder

170 V

100 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS100.TXLR

Littelfuse

Electric Fuse

Inline/Holder

170 V

100 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS100.ZXLR

Littelfuse

Electric Fuse

Inline/Holder

170 V

100 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS100.T

Littelfuse

Electric Fuse

Inline/Holder

170 V

100 A

End Cap

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.