150 A Fuses 262

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LPJ-150SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

LPJ-150SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.63 in (41.4 mm)

J

600 V

Indicator

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

FWP-150A

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

150 A

Tab/Blade

2.9 kJ

50 kA

Box

1.5 in (38.1 mm)

1.5 x 2.84 in (38.1 x 72.14 mm)

2.84 in (72.136 mm)

CE; CSA; UL

AJT150

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.614 in (41 mm)

Indicator

1.614 x 2.992 in (41 x 76 mm)

5.748 in (146 mm)

Time Delay

FLSR150.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

Indicator

9.626 in (244.5 mm)

CSA; UL

Time Delay

SP/LPJ-150SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

Silver

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

e4

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

AJT150/400

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

2.126 in (54 mm)

J

600 V

7.126 in (181 mm)

IEC, UL

Time Lag

AJT150EI

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

Indicator

3.22 in (81.8 mm)

3.22 in (81.8 mm)

UL

Time Delay

AJT150N

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

1.614 in (41 mm)

5.748 in (146 mm)

CSA; IEC; UL

Time Delay

KRP-CL-150

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

150 A

Tab/Blade

200 kA

2.402 in (61 mm)

600 V

2.402 x 3.752 in (61 x 95.3 mm)

3.752 in (95.3 mm)

UL

Time Delay

ECSR150

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

150 A

Tab/Blade

200 kA

10 s

Pre Arcing Time: Open within 10 s at 500% Rated Current

Bulk

0.063 in (1.61 mm)

0.379 in (9.63 mm)

CE; CUL; UL

Time Delay

FRS-R-150

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

1.839 in (46.7 mm)

RK5

600 V

1.839 x 9.626 in (46.7 x 244.5 mm)

9.626 in (244.5 mm)

CE; CSA; UL

Time Delay

142.5631.6152

Littelfuse

Electric Fuse

Inline/Holder

58 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

Matte Tin

1 kA

100 ms

83400

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.472 x 0.307 x 0.63 in (12 x 7.8 x 16 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

MEV100A150-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

150 A

Tab/Blade

100 kA

80 ms

Bulk

1.22 in (31 mm)

2.874 in (73 mm)

IATF 16949; UL

0JTD150.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

142.5395.6152

Littelfuse

Electric Fuse

Inline/Holder

58 V

150 A

Tab/Blade

113.4 kJ

-40 °C (-40 °F)

1 kA

100 ms

1.142 in (29 mm)

58 V

1.142 x 0.74 x 0.366 in (29 x 18.8 x 9.3 mm)

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

L25S150

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.626 in (31 x 41.3 mm)

1.626 in (41.3 mm)

CE; CSA; UL

Very Fast

NON-150

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

10 kA

Rated Breaking Capacity at 125 VDC: 10000 A

Box

1.56 in (39.62 mm)

H

250 V

1.56 x 7.13 in (39.62 x 181.1 mm)

7.13 in (181.1 mm)

CE; CSA; UL

0498150.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0AKRBK150-BB

Bel Fuse

Electric Fuse

Inline/Holder

500 V

150 A

Tab/Blade

-40 °C (-40 °F)

Tin

50 kA

Bulk

1.929 in (49 mm)

1.457 in (37 mm)

e3

0.945 in (24 mm)

105 °C (221 °F)

JDL150

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

150 A

300 kA

JDL

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; UL

Time Delay

FLNR150ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

Indicator

1.594 x 7.126 in (40.5 x 181 mm)

7.126 in (181 mm)

CSA; QPL; UL

Time Delay

FLNR.150ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

Indicator

1.594 x 7.126 in (40.5 x 181 mm)

7.126 in (181 mm)

CSA; QPL; UL

Time Delay

3298150.ZXM10

Littelfuse

Electric Fuse

Panel Mount

32 V

150 A

Wraparound

81.6 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

Time Delay

L50QS150.V

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

150 A

Tab/Blade

2.382 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1.218 in (30.94 mm)

10 ms

2.125 in (53.98 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0498150.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

Matte Tin

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

FLNR150.X

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

1.535 in (39 mm)

7.126 in (181 mm)

CSA; UL

Time Delay

L70QS150.V

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

150 A

Tab/Blade

3.026 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

1.218 in (30.94 mm)

2.875 in (73.03 mm)

CUL; UL

125 °C (257 °F)

Very Fast

PF-FB2-150

Bourns

Electric Fuse

Inline/Holder

800 V

800 V

150 A

Tab/Blade

16.9 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 800 VDC: 50000 A

Bulk

0.949 in (24.1 mm)

2.598 in (66 mm)

CUL; UL

125 °C (257 °F)

0298150.TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0298150TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

FLNR150.XXID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

1.535 in (39 mm)

Indicator

7.126 in (181 mm)

CSA; UL

Time Delay

JLLS150.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

0CNN150E.V

Littelfuse

Electric Fuse

Inline/Holder

80 V

150 A

Tab/Blade

2.7 kA

3.181 in (80.8 mm)

80 V

3.18 in (80.77 mm)

CUL; UL

Very Fast

142.7010.6152

Littelfuse

Electric Fuse

Inline/Holder

58 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

Tin

1 kA

100 ms

83400

0.63 in (16 mm)

0.472 in (12 mm)

e3

58 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

153.5631.6151

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

83400

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

3298150.Z

Littelfuse

Electric Fuse

Surface Mount

32 V

150 A

Wraparound

75 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.181 in (30 mm)

1.047 in (26.6 mm)

Mega

0.63 in (16 mm)

125 °C (257 °F)

JLS150

Littelfuse

Electric Fuse

Inline/Holder

600 V

150 A

Tab/Blade

200 kA

Bulk

1.5 in (38.1 mm)

1.5 x 3 in (38.1 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; QPL; UL

Fast

L13S150

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

150 A

Tab/Blade

100 kA

L13S

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

IDSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

TLN150

Littelfuse

Electric Fuse

Inline/Holder

170 V

150 A

Tab/Blade

Rated Breaking Capacity at 170 VDC: 100000 A

1.594 in (40.5 mm)

1.594 x 4.173 in (40.5 x 106 mm)

4.173 in (106 mm)

UL

Fast

LCY150ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

LCY

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

150-5R-1B-2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

Tab/Blade

390 A

Rated Breaking Capacity=390A-80000A

3 in (76.2 mm)

Indicator

3 x 13 in (76.2 x 330.2 mm)

13 in (330.2 mm)

Medium

LA15QS150-4TI

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

150 A

Tab/Blade

6.8 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.13 in (28.7 mm)

Indicator

1.13 x 1.161 in (28.7 x 29.5 mm)

1.161 in (29.5 mm)

UL

Very Fast

5NLE-150ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

153.0020.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

150-5R-1BI-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

Tab/Blade

400 A

Rated Breaking Capacity=400A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

0498150.MXT-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.