150 A Fuses 262

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0496150

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Pin Wire

-40 °C (-40 °F)

300 ms

2.394 in (60.8 mm)

0.72 in (18.3 mm)

2.394 x 0.72 x 0.661 in (60.8 x 18.3 x 16.8 mm)

0.661 in (16.8 mm)

UL

125 °C (257 °F)

Time Delay

FLSR150ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

Indicator

1.843 x 9.626 in (46.8 x 244.5 mm)

9.626 in (244.5 mm)

CSA; QPL; UL

Time Delay

0298150.UXP-NH

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

97.3 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

150E-3CL-15.5

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

Tab/Blade

60 kA

11.56 in (293.62 mm)

11.56 x 19.1 in (293.62 x 485.14 mm)

19.1 in (485.14 mm)

Medium

RLS150

Littelfuse

Electric Fuse

Inline/Holder

600 V

150 A

Tab/Blade

10 kA

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CE; CSA; UL

0298150.ZXEH-LT

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

59 kJ

-40 °C (-40 °F)

2 kA

100 ms

59000

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

156.5610.6152

Littelfuse

Electric Fuse

Inline/Holder

36 V

150 A

Tab/Blade

-40 °C (-40 °F)

625 A

1 m

Bulk

1.614 in (41 mm)

0.433 in (11 mm)

0.039 in (1 mm)

125 °C (257 °F)

150-5R-1B-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

Tab/Blade

390 A

Rated Breaking Capacity=390A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

JLLN150P

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

EV1K150

Littelfuse

Electric Fuse

Inline/Holder

1 KV

150 A

Tab/Blade

5 kJ

-40 °C (-40 °F)

30 kA

Bulk

1.218 in (30.94 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

0RLN150.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

150 A

Tab/Blade

10 kA

1.563 in (39.7 mm)

7.126 in (181 mm)

CE; CSA; UL

LLNRK150.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

7.126 in (181 mm)

CE; CSA; UL; QPL

Time Delay

KLSR0150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CE; CSA; UL

Fast

KLNR0150

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

7.126 in (181 mm)

CE; CSA; UL

Fast

LLSRK150.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

Indicator

9.626 in (244.5 mm)

CE; CSA; UL; QPL

Time Delay

0RLS150.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

150 A

Tab/Blade

10 kA

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CE; CSA; UL

L70QS150

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

150 A

Tab/Blade

3.026 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

1.218 in (30.94 mm)

2.875 in (73.03 mm)

CUL; UL

125 °C (257 °F)

Very Fast

0KLC150.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

150 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

1.5 in (38.1 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L17T150.T

Littelfuse

Electric Fuse

Inline/Holder

170 V

150 A

Tab/Blade

100 kA

Bulk

1 in (25.4 mm)

1.157 in (29.4 mm)

CSA; UL

153.0020.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

150-5R-1BI-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

Tab/Blade

400 A

Rated Breaking Capacity=400A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

0498150.MXT-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.