150 A Fuses 262

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

5NLE-150ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

0898150.U-NH

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

58.1 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

2CC150

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

150 A

Tab/Blade

200 kA

2CC

Rated Breaking Capacity at 250 VDC: 80000 A

1.614 in (41 mm)

1.614 x 2.992 in (41 x 76 mm)

2.992 in (76 mm)

CSA

LLSRK150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

1.843 x 9.626 in (46.8 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

LLSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

20 kA

Rated Breaking Capacity at 300 VDC: 20000

1.843 in (46.8 mm)

1.843 x 6.689 in (46.8 x 169.9 mm)

6.689 in (169.9 mm)

Time Delay

L15S150

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

150 A

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L50S150

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

150 A

Tab/Blade

Silver

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1.22 in (31 mm)

e4

1.22 x 2.126 in (31 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

4998150.M-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

45.1 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.323 in (8.2 mm)

UL

125 °C (257 °F)

8NLE-65EL

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

8NLE-65E

3 in (76.2 mm)

3 x 17.874 in (76.2 x 454 mm)

17.874 in (454 mm)

150-5R-1C-5.5XW

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

390 A

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

15NLE3-150EL

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

15NLE3-150E

9.748 in (247.6 mm)

9.748 x 23.874 in (247.6 x 606.4 mm)

23.874 in (606.4 mm)

0498150.MXTM6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0298150.UXP-2M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

97.3 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

LCX150E

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

80 kA

LCX

6.38 in (162.05 mm)

6.38 x 10.875 in (162.05 x 276.23 mm)

10.875 in (276.23 mm)

Medium

0498150.MX1M5-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0CCK150.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

150 A

Tab/Blade

10 kA

1.06 in (26.92 mm)

4.72 in (119.88 mm)

Time Delay

LA30QS150-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

150 A

Tab/Blade

9.3 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

JLLS150.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.079 in (27.4 mm)

600 V

1.657 in (42.1 mm)

CE; CSA; UL

Fast

150E1C2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

3 x 10.875 in (76.2 x 276.23 mm)

10.874 in (276.2 mm)

Medium

157.5700.6151

Littelfuse

Electric Fuse

Inline/Holder

48 V

150 A

Tab/Blade

-40 °C (-40 °F)

900 A

200 ms

Bulk

3.228 in (82 mm)

0.787 in (20 mm)

0.031 in (0.8 mm)

125 °C (257 °F)

150-5R-1C-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

440 A

15 s

3 in (76.2 mm)

Striker

3 x 15.875 in (76.2 x 403.23 mm)

15.874 in (403.2 mm)

40 °C (104 °F)

Medium

NLS150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

50 kA

Rated Breaking Capacity at 600 VDC; 50000

1.843 in (46.8 mm)

1.843 x 6.878 in (46.8 x 174.7 mm)

6.878 in (174.7 mm)

CSA; UL

3998150.ZXM10

Littelfuse

Electric Fuse

Surface Mount

80 V

150 A

Wraparound

81.6 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

150E-1C-5.5L

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

150E-1C-5.5

3 in (76.2 mm)

3 x 15.874 in (76.2 x 403.2 mm)

15.874 in (403.2 mm)

150-5R-1C-8.25W

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

440 A

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

150-5R-1IB-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

Tab/Blade

390 A

Rated Breaking Capacity=390A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

150E-2CL-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

Tab/Blade

80 kA

7.94 in (201.68 mm)

7.94 x 16.131 in (201.68 x 409.72 mm)

16.131 in (409.72 mm)

Medium

LCU150ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

LCU

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

LCL5RS

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

390 A

LCL

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

LDC0150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

0CNN150.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

150 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

15GSE2150E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 21.915 in (162.05 x 556.63 mm)

21.875 in (555.63 mm)

Medium

LCL5RW

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

390 A

LCL

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

KLW150

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

150 A

Tab/Blade

100 kA

KLW

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

JLLN150

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

1.063 x 0.843 in (27 x 21.4 mm)

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

0998150.U-1M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

72 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.21 mm)

0.75 in (19.05 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

0498150.MXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0298150.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

LCL5R

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

390 A

LCL

Rated Breaking Capacity=390A-80000A

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

0298150ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

153.7000.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

LDZ150ES

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

LDZ

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

150E-1C-2.75L

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

80 kA

150E-1C-2.75

3 in (76.2 mm)

3 x 10.874 in (76.2 x 276.2 mm)

10.874 in (276.2 mm)

KLSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CSA; UL

Fast

0898150.U-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

58.1 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

JTD150ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Indicator

1.626 x 3 in (41.3 x 76.2 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

0298150

Littelfuse

Electric Fuse

150 A

-40 °C (-40 °F)

2 kA

100000

2.7 in (68.58 mm)

0.75 in (19.05 mm)

32 V

352 μΩ

2.7 x 0.75 x 0.42 in (68.58 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0498150.MX1M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.