150 A Fuses 262

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

4998150.M-NH

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

45.1 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.323 in (8.2 mm)

UL

125 °C (257 °F)

KLNR150

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

150 A

Tab/Blade

200 kA

KLNR

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

7.126 in (181 mm)

CSA; UL

Fast

LA50QS150-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

150 A

Tab/Blade

9 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

1.22 in (31 mm)

500 V

1.22 x 2.13 in (31 x 54.1 mm)

2.13 in (54.1 mm)

CSA; UL

Fast

8NLE2150E

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 17.87 in (162.05 x 453.89 mm)

17.875 in (454.03 mm)

Medium

153.5395.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

113.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.142 in (29 mm)

0.642 in (16.3 mm)

32 V

0.366 in (9.3 mm)

UL

125 °C (257 °F)

Slow

CNN150E

Littelfuse

Electric Fuse

Inline/Holder

125 V

80 V

150 A

Tab/Blade

2.7 kA

3.181 in (80.8 mm)

3.18 in (80.77 mm)

CUL; UL

Very Fast

0998150.UX-1M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

58.1 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

LA30QS150-4TI

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

150 A

Tab/Blade

9.3 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

Indicator

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

157.5701.6151

Littelfuse

Electric Fuse

Inline/Holder

48 V

150 A

Tab/Blade

-40 °C (-40 °F)

900 A

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

LA15QS150-4IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

150 A

Tab/Blade

6.8 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.13 in (28.7 mm)

1.13 x 1.161 in (28.7 x 29.5 mm)

1.161 in (29.5 mm)

UL

Very Fast

0998150.UX-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

58.1 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

LCK5RW

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

390 A

LCK

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 10.875 in (76.2 x 276.23 mm)

10.875 in (276.23 mm)

Medium

3298150.H

Littelfuse

Electric Fuse

Surface Mount

32 V

150 A

Wraparound

75 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.181 in (30 mm)

1.047 in (26.6 mm)

Mega

0.63 in (16 mm)

125 °C (257 °F)

0298150ZXEH-UL

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

UL

125 °C (257 °F)

Time Delay

LDC150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

0998150.UX-NH

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

58.1 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

150-5R-1C-5.5W

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

390 A

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

153.5631.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

83400

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

150-5R-1C-5.5S

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

390 A

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

150-5R-1C-2.75W

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

390 A

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 10.875 in (76.2 x 276.23 mm)

10.875 in (276.23 mm)

Medium

CBO150

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

10 kA

0.812 in (20.62 mm)

0.812 x 1.625 in (20.62 x 41.28 mm)

1.623 in (41.23 mm)

Fast

150E-2C-15.5L

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

150E-2C-15.5

6.378 in (162 mm)

6.378 x 18.874 in (162 x 479.4 mm)

18.874 in (479.4 mm)

LDN150ES

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

80 kA

LDN

Hermitically Sealed Part Number

9.726 in (247.05 mm)

9.726 x 18.875 in (247.05 x 479.43 mm)

18.875 in (479.43 mm)

Medium

8NLE2-150ES

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 17.87 in (162.05 x 453.89 mm)

17.87 in (453.89 mm)

Medium

2CM150

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

150 A

Tab/Blade

200 kA

2CM

Rated Breaking Capacity at 250 VDC: 80000 A

1.614 in (41 mm)

1.614 x 3.031 in (41 x 77 mm)

3.031 in (77 mm)

CSA

150-5R-1IB-2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

Tab/Blade

390 A

Rated Breaking Capacity=390A-80000A

3 in (76.2 mm)

Indicator

3 x 13 in (76.2 x 330.2 mm)

13 in (330.2 mm)

Medium

0898150.U-2M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

58.1 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

LA70QS150-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

150 A

Tab/Blade

11 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

CNN150

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

150 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

2.43 in (61.72 mm)

UL

Very Fast

153.7010.6151

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

Tin

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

JLLN150.X

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

300 V

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

150E-1C-8.25S

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

150E-2C-2.75L

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

80 kA

150E-2C-2.75

6.378 in (162 mm)

6.378 x 10.874 in (162 x 276.2 mm)

10.874 in (276.2 mm)

0498150.MX1M5

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

81.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.327 in (16 x 12 x 8.3 mm)

0.327 in (8.3 mm)

125 °C (257 °F)

Time Delay

0998150.U-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

150 A

Tab/Blade

72 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.21 mm)

0.75 in (19.05 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

298150

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

2 kA

Rated Breaking Capacity at 32 VDC: 2000 A

100000

1.15 in (29.21 mm)

0.75 in (19.05 mm)

32 V

352 μΩ

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

Slow

150-5R-1C-2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

390 A

15 s

3 in (76.2 mm)

Striker

3 x 10.875 in (76.2 x 276.23 mm)

10.874 in (276.2 mm)

40 °C (104 °F)

Medium

LA100P150-4TI

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

150 A

Tab/Blade

41 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

1.5 in (38.1 mm)

Indicator

1.5 x 3.469 in (38.1 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

0298150.ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

FLSR150.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

15NLE3150E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

10 m

9.752 in (247.7 mm)

Striker

9.75 x 23.875 in (247.65 x 606.43 mm)

23.875 in (606.43 mm)

Medium

0298150.ZXB

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.132 x 0.75 x 0.42 in (28.75 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

L13S150

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

150 A

Tab/Blade

100 kA

L13S

Rated Breaking Capacity at 100 VDC: 20000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Fast

IDSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

TLN150

Littelfuse

Electric Fuse

Inline/Holder

170 V

150 A

Tab/Blade

Rated Breaking Capacity at 170 VDC: 100000 A

1.594 in (40.5 mm)

1.594 x 4.173 in (40.5 x 106 mm)

4.173 in (106 mm)

UL

Fast

LCY150ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

LCY

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

150-5R-1B-2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

Tab/Blade

390 A

Rated Breaking Capacity=390A-80000A

3 in (76.2 mm)

Indicator

3 x 13 in (76.2 x 330.2 mm)

13 in (330.2 mm)

Medium

LA15QS150-4TI

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

150 A

Tab/Blade

6.8 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.13 in (28.7 mm)

Indicator

1.13 x 1.161 in (28.7 x 29.5 mm)

1.161 in (29.5 mm)

UL

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.