600 V Fuses 1,047

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

IDSR004ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

07945810198

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

End Cap

2.379 J

-55 °C (-67 °F)

100 kA

145 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

291 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

IDSR225ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

225 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

LDC500

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

LDC350

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

350 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

KLKD002.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

End Cap

12 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLKD03.5H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.5 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

PSR030FS0550Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Threaded

44.323 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

07945810205

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

End Cap

130.266 J

-55 °C (-67 °F)

100 kA

541 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

945 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

PSR031UL0400Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

400 A

Tab/Blade

14.77 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD31/2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.5 A

End Cap

12.417 J

-55 °C (-67 °F)

100 kA

249 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

471 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

07945894353

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

15 A

Tab/Blade

137.333 J

-55 °C (-67 °F)

100 kA

544 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

1.721 ms

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

LA60Q12-2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

12 A

End Cap

150 J

200 kA

Rated Breaking Capacity at 600 VDC: 100000 A

0.406 in (10.32 mm)

0.406 x 1.5 in (10.32 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

PSR033FS0700H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

700 A

Threaded

56.763 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

IDSR035ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

35 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR002ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

PSR033FS0500Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Threaded

16.434 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

2.008 in (51 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

0LDC1000.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR01.4ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.4 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

KLKD003.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

End Cap

-55 °C (-67 °F)

Nickel

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR031UL0550Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Tab/Blade

42.056 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR2.80

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.8 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC; 20000

Indicator

CSA; MSHA; UL

Time Delay

KLKD025.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

2.085 kJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

LDC1500

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.5 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

KLKD7

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

7 A

End Cap

105.143 J

-55 °C (-67 °F)

100 kA

505 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

898 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

IDSR090ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

90 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR450.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

3.043 in (77.3 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

PSR031UL0500Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Tab/Blade

29.751 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD008

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

End Cap

656 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

PSR030FL0250Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

250 A

Threaded

4.668 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

IDSR100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

IDSR4.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4.5 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC; 20000

Indicator

CSA; MSHA; UL

Time Delay

KLKD.100R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR031US0400Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

400 A

Tab/Blade

14.77 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD.250

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

250 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR032US1100X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1.1 kA

Tab/Blade

225.379 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR01.8T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.8 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR.800

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR031US0500Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Tab/Blade

29.751 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR032UL1100X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1.1 kA

Tab/Blade

225.379 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR600.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR032UL0400X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

400 A

Tab/Blade

11.104 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD030.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

30 A

End Cap

3.22 kJ

-55 °C (-67 °F)

Nickel

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR030US0200Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

200 A

Tab/Blade

3.012 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR.800T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR032UL0550X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Tab/Blade

26.327 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

07945894351

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

Tab/Blade

130.266 J

-55 °C (-67 °F)

100 kA

541 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

945 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

PSR031FS0550Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Threaded

42.056 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.