600 V Fuses 1,047

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSR030UL0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Tab/Blade

23.133 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

NLS110

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

110 A

Tab/Blade

50 kA

Rated Breaking Capacity at 600 VDC; 50000

1.843 in (46.8 mm)

1.843 x 6.878 in (46.8 x 174.7 mm)

6.878 in (174.7 mm)

CSA; UL

IDSR050ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

50 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

PSR030FS0050Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

50 A

Threaded

110 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR03.2T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.2 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

LDC300

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

300 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

PSR030UL0080Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

80 A

Tab/Blade

304 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD20

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

462.056 J

-55 °C (-67 °F)

100 kA

826 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

6.144 ms

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

LDC900

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

900 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR010

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

10 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LDC0400

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

IDSR250ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

250 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR350

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

2.5 x 11.626 in (63.5 x 295.3 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

KLKD1-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

Tab/Blade

678 mJ

-55 °C (-67 °F)

100 kA

94 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

247 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

PSR030FS0125Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

125 A

Threaded

707 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR040.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

40 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.063 in (27 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

PSR033FS0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Threaded

13.6 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

2.008 in (51 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

07945812133

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

Tab/Blade

678 mJ

-55 °C (-67 °F)

100 kA

94 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

247 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

IDSR01.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD020.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

100 kA

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

IDSR045ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

45 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

PSR030UL0040Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

40 A

Tab/Blade

76 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR030US0160Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

160 A

Tab/Blade

1.359 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD020.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

2.12 kJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

0LDC1400.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.4 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

L

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

LDC250

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

250 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

PSR033FS0900H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

900 A

Threaded

122.619 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

07945810207

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

12 A

End Cap

445.01 J

-55 °C (-67 °F)

100 kA

822 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

1.455 ms

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

IDSR080ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

80 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

PSR032UL0450X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Tab/Blade

15.535 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR031US0800Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Tab/Blade

137.208 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR033FL1100Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1.1 kA

Threaded

310.824 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

2.008 in (51 mm)

Indicator

4.268 in (108.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR033FL1000Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1 kA

Threaded

222.35 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

2.008 in (51 mm)

Indicator

4.268 in (108.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

0LDC1100.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.1 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

KLKD3-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

Tab/Blade

7.821 J

-55 °C (-67 °F)

100 kA

211 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

449 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

LDC1601

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.601 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

PSR030FL0160Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

160 A

Threaded

1.359 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

IDSR175ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

175 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR080

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

31.8mm x 200mm

7.874 in (200 mm)

CSA; UL

Time Delay

PSR033US1100X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1.1 kA

Tab/Blade

310.824 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

07945810194

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

141 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

0506016MXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

16 A

End Cap

61 J

-55 °C (-67 °F)

Nickel

10 kA

61

Bulk

0.25 in (6.35 mm)

600 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Fast

LDC700

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

700 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CSA; UL

Fast

PSR033FL0500H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Threaded

16.434 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

KLKD005.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

End Cap

100 kA

KLKD

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

PSR033US0800X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Tab/Blade

84.691 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR031FL0700Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

700 A

Threaded

98.187 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.