600 V Fuses 1,047

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSR031FL0550Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Threaded

42.056 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

KLKD006.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

35 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

KLKD30-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

30 A

Tab/Blade

1.409 kJ

-55 °C (-67 °F)

100 kA

1.207 ms

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

2.266 ms

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Fast

07945810192

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

250 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

0506020MXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

105 J

-55 °C (-67 °F)

Nickel

10 kA

105

Bulk

0.25 in (6.35 mm)

600 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Fast

KLKD009.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

9 A

End Cap

100 kA

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

KLKD015

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

15 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

137.3

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLKD.250H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

250 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR030UL0315Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

315 A

Tab/Blade

7.131 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR04.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4.5 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD009.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

9 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

IDSR.150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD008R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

End Cap

656 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

IDSR002

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

0LDC1900.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.9 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3.5 in (88.9 mm)

L

600 V

3.5 x 3.752 in (88.9 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR500ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR1.60

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.6 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC; 20000

Indicator

CSA; MSHA; UL

Time Delay

IDSR001

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR080.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

07945810200

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

End Cap

7.821 J

-55 °C (-67 °F)

100 kA

211 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

449 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

PSR030US0063Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

63 A

Tab/Blade

176 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR01.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.8 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

LDC400

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

400 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

IDSR010.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

10 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR17.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

17.5 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR030UL0500Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Tab/Blade

31.429 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR450

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

3.043 in (77.3 mm)

3 x 13.374 in (76.2 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

0LDC1600.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.6 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

L

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR400.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

400 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

NLS070

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

70 A

Tab/Blade

50 kA

Rated Breaking Capacity at 600 VDC; 50000

1.311 in (33.3 mm)

1.311 x 5.874 in (33.3 x 149.2 mm)

5.874 in (149.2 mm)

CSA; UL

PSR030UL0250Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

250 A

Tab/Blade

4.668 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR031FL0315Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

315 A

Threaded

6.862 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

IDSR020ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

20 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR2.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

0LDC1800.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.8 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3.5 in (88.9 mm)

L

600 V

3.5 x 3.752 in (88.9 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR01.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.5 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LDC0650

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

650 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

IDSR175

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

175 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

IDSR1.80

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.8 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC; 20000

Indicator

CSA; MSHA; UL

Time Delay

PSR030US0050Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

50 A

Tab/Blade

110 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD.500T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

IDSR01.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.5 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD008.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

End Cap

656 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

PSR031FL0200Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

200 A

Threaded

1.965 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

IDSR03.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.5 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LA60Q40-2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

40 A

End Cap

1.8 kJ

200 kA

Rated Breaking Capacity at 600 VDC: 100000 A

0.406 in (10.32 mm)

0.406 x 1.5 in (10.32 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

KLKD.125

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

125 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR030FS0080Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

80 A

Threaded

304 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.