Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSR032UL0550X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Tab/Blade

26.327 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

07945894351

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

Tab/Blade

130.266 J

-55 °C (-67 °F)

100 kA

541 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

945 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

PSR031FS0550Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Threaded

42.056 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR031US0700Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

700 A

Tab/Blade

98.187 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

07945894352

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

12 A

Tab/Blade

445.01 J

-55 °C (-67 °F)

100 kA

822 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

1.455 ms

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

IDSR11/2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.125 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR031FL0400Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

400 A

Threaded

14.77 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

IDSR01.6T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR031FS0800Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Threaded

137.208 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD03.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.5 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

PSR032US0450X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Tab/Blade

15.535 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR025

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR009

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD004.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4 A

End Cap

100 kA

KLKD

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

KLKD1

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

678 mJ

-55 °C (-67 °F)

100 kA

94 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

247 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

IDSR200.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR033US0450X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Tab/Blade

13.6 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

1.976 in (50.2 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR.200T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR031FS0630Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

630 A

Threaded

45.403 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

NLS003

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

End Cap

50 kA

Rated Breaking Capacity at 600 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

PSR033FL0500Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Threaded

16.434 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

2.008 in (51 mm)

Indicator

4.268 in (108.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR032US0550X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

550 A

Tab/Blade

26.327 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR060

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

60 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.063 in (27 mm)

1 x 5.5 in (25.4 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

IDSR.300T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

300 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR5.60

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5.6 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC; 20000

Indicator

CSA; MSHA; UL

Time Delay

IDSR005ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

07945810211

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

30 A

End Cap

1.409 kJ

-55 °C (-67 °F)

100 kA

1.207 ms

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

2.266 ms

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

KLKD2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

End Cap

2.379 J

-55 °C (-67 °F)

Nickel

100 kA

145 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

291 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

PSR030US0250Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

250 A

Tab/Blade

4.668 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

07945810206

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

10 A

End Cap

278.39 J

-55 °C (-67 °F)

100 kA

701 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

1.2 ms

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

NLS70

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

70 A

Tab/Blade

50 kA

1.311 in (33.3 mm)

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

IDSR003

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD010.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

10 A

End Cap

211.667 J

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

LDC0800

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

IDSR015ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

15 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR110.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

KLKD015R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

15 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

IDSR002.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR033FL1100H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1.1 kA

Threaded

310.824 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

KLKD10

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

10 A

End Cap

278.39 J

-55 °C (-67 °F)

100 kA

701 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

1.2 ms

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

IDSR200ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

KLKD025R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

2.085 kJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

PSR030FL0350Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Threaded

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

0LDC601.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

601 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, UL

Fast

KLKD5

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

End Cap

34.163 J

-55 °C (-67 °F)

100 kA

347 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

607 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

IDSR2.25T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR032UL0700X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

700 A

Tab/Blade

51.191 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

IDSR600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

3.043 in (77.3 mm)

3 x 13.374 in (76.2 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.