600 V Fuses 1,047

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSR030UL0350Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

350 A

Tab/Blade

12.007 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

0LDC1500.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.5 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

L

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

KLKD015.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

15 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

PSR031FS0200Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

200 A

Threaded

1.965 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

NLS004

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4 A

End Cap

50 kA

Rated Breaking Capacity at 600 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

PSR030FS0250Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

250 A

Threaded

4.668 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

07945810203

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

62.951 J

-55 °C (-67 °F)

100 kA

423 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

735 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

PSR033FL0900H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

900 A

Threaded

122.619 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

IDSR006ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

IDSR01.4

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.4 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

PSR030FS0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Threaded

23.133 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

07945810191

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

73 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

PSR032FL0700Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

700 A

Threaded

51.191 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

2.008 in (51 mm)

Indicator

3.736 in (94.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

LA60Q25-2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

440 J

200 kA

Rated Breaking Capacity at 600 VDC: 100000 A

0.406 in (10.32 mm)

0.406 x 1.5 in (10.32 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

PSR032UL0500X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

500 A

Tab/Blade

21.573 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

0506015MXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

61 J

-55 °C (-67 °F)

Nickel

10 kA

61

Bulk

0.25 in (6.35 mm)

600 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Fast

0LDC800.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

800 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

LDC0900

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

900 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

PSR033FS1000H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1 kA

Threaded

222.35 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

PSR030FS0100Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

100 A

Threaded

437 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

0LDC600.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

600 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, UL

Fast

KLKD.500R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

IDSR003ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

0LDC650.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

650 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, UL

Fast

0LDC900.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

900 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

PSR032US0700X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

700 A

Tab/Blade

51.191 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

KLKD010.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

10 A

End Cap

211.667 J

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLKD.750

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

750 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

LA60Q35-2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

35 A

End Cap

1.3 kJ

200 kA

Rated Breaking Capacity at 600 VDC: 100000 A

0.406 in (10.32 mm)

0.406 x 1.5 in (10.32 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

07945810214

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3.5 A

End Cap

12.417 J

-55 °C (-67 °F)

100 kA

249 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

471 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

KLKD007.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

7 A

End Cap

100 kA

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

KLKD006.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

100 kA

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

KLKD02.5H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.5 A

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

LDC750

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

750 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, UL

Fast

IDSR006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR009ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

9 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

PSR033FL1000H

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

1 kA

Threaded

222.35 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.008 in (51 mm)

2.894 in (73.5 mm)

Indicator

3.13 in (79.5 mm)

CCC; CE; CUL; UL; IEC

125 °C (257 °F)

Fast

IDSR150ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

KLKD030.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

30 A

End Cap

3.22 kJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

IDSR035

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.063 in (27 mm)

1 x 5.5 in (25.4 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

KLKD1/2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

141 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

PSR031FL0630Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

630 A

Threaded

45.403 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

IDSR1.12

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.125 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

IDSR004

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD30

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

30 A

End Cap

1.409 kJ

-55 °C (-67 °F)

100 kA

1.207 ms

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

2.266 ms

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

07945814859

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

Tab/Blade

34.163 J

-55 °C (-67 °F)

100 kA

347 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

607 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

KLKD020R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

2.12 kJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

LDC0601

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

601 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.