Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Carlisle Interconnect Technologies |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
.05 ohm |
SILVER |
YES |
EXTRUDED PTFE |
200 Cel |
NO |
NO |
-55 Cel |
22 |
1.37 mm |
1 |
STANDARD: MIL-W-16878 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
|||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
CROSSLINKED EXTRUDED MODIFIED ETFE |
150 Cel |
24 |
.037 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
||||||||||||||||||||||||||
|
Belden |
CABLE ASSEMBLY |
M12 MALE |
M12 FEMALE |
30 V |
1.5 A |
NO |
UL |
.25 mm2 |
COPPER ALLOY |
POLYURETHANE |
NO |
POLYPROPYLENE |
80 Cel |
NO |
NO |
-50 Cel |
23 |
6.4 mm |
12 |
5 mm |
COMMUNICATION CABLE |
||||||||||||||||||
|
TE Connectivity |
CABLE ASSEMBLY |
250 V |
4 A |
NO |
COPPER ALLOY |
22 AWG |
POLYVINYLCHLORIDE |
22 |
STRAIGHT |
SCREW |
5 mm |
M12 |
COMMUNICATION CABLE |
250 V |
|||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
FEMALE CONNECTOR |
FEMALE CONNECTOR |
2.6 A |
NO |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
POLYVINYL CHLORIDE |
105 Cel |
-40 Cel |
28 |
10 |
.203 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
TERMINAL |
TERMINAL |
300 V |
2.6 A |
NO |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
28 |
20 |
.279 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
SOCKET |
SOCKET |
300 V |
2.8 A |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
28 |
20 |
.254 mm |
FLAT CABLE |
7X36 |
|||||||||||||||||
Infinite Electronics International |
CABLE ASSEMBLY |
RJ45 PLUG |
RJ45 PLUG |
NO |
COPPER ALLOY |
STRANDED |
POLYVINYL CHLORIDE |
NO |
NO |
ETHERNET, CATEGORY 5E |
NO |
8 |
7.62 mm |
COMMUNICATION CABLE |
||||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; UL |
.326 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.054 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-20 Cel |
22 |
5.77 mm |
6 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
7X30 |
|||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
600 V |
NO |
BS; CUL; DIN; IEC; UL; VDE |
4 mm2 |
BARE COPPER |
STRANDED |
POLYMER |
NO |
POLYMER |
80 Cel |
NO |
FIXED INSTALLATION |
NO |
-40 Cel |
12 |
13.8 mm |
4 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; EAC; IPA; VDE |
4 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
POLYVINYL CHLORIDE |
80 Cel |
FLEXIBLE USE FOR MEDIUM MECHANICAL, STRESSES WITH FREE MOVES |
-40 Cel |
12 |
10.4 mm |
3 |
CONTROL CABLE |
|||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.35 A |
NO |
UL |
.01 mm2 |
COPPER ALLOY |
FLAT |
2.2 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
37 |
20 |
FLAME RESISITANT |
.051 mm |
FLAT CABLE |
||||||||||||||||||
|
Phoenix Contact |
CABLE ASSEMBLY |
PLUG STRAIGHT |
SOCKET STRAIGHT |
30 V |
2 A |
NO |
CUL; EAC; UL |
.25 mm2 |
BARE COPPER LITZ |
STRANDED |
PUR |
.078 ohm |
NO |
PP |
80 Cel |
NO |
NO |
-40 Cel |
24 |
5.9 mm |
8 |
1.5 mm |
COMMUNICATION CABLE |
32X0.10 |
|||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
COPPER ALLOY |
FLAT |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
8 |
.254 mm |
FLAT CABLE |
|||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; EAC |
.75 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
18 |
2.2 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
195X0.07 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
1000 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
POLYVINYLCHLORIDE |
80 Cel |
-40 Cel |
14 |
2.69 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
5000 V |
NO |
.823 mm2 |
COPPER ALLOY |
STRANDED |
.022 ohm |
TIN |
NO |
ETHYLENE PROPYLENE RUBBER |
90 Cel |
NO |
NO |
-30 Cel |
18 |
3.48 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
65X36 |
|||||||||||||||||||
|
Phoenix Contact |
CABLE ASSEMBLY |
PLUG STRAIGHT |
SOCKET ANGLED |
24 V |
4 A |
NO |
CUL; EAC; UL |
.34 mm2 |
BARE COPPER LITZ |
STRANDED |
PUR |
.058 ohm |
NO |
PP |
80 Cel |
NO |
NO |
-40 Cel |
22 |
4.2 mm |
4 |
.3 mm |
COMMUNICATION CABLE |
42X0.10 |
|||||||||||||||
|
Phoenix Contact |
CABLE ASSEMBLY |
PLUG ANGLED |
SOCKET ANGLED |
24 V |
4 A |
NO |
CUL; EAC; UL |
.34 mm2 |
BARE COPPER LITZ |
STRANDED |
PUR |
.058 ohm |
NO |
PP |
80 Cel |
NO |
NO |
-40 Cel |
22 |
4.2 mm |
4 |
3 mm |
COMMUNICATION CABLE |
42X0.10 |
|||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
.082 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
24 |
1.12 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||
Amphenol |
WIRE AND CABLE |
300 V |
1 A |
NO |
CSA, UL |
TINNED COPPER |
STRANDED |
.24 ohm |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
NO |
28 |
40 |
30.48 mm |
FLAT RIBBON CABLE |
7X36 |
||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
30 V |
.5 A |
NO |
.03 mm2 |
COPPER |
FLAT |
.73 ohm |
TIN |
NO |
POLYIMIDE |
80 Cel |
NO |
NO |
-40 Cel |
32 |
20 |
PREMO-FLEX |
.127 mm |
FLAT FLEXIBLE CABLE |
|||||||||||||||||||
|
TE Connectivity |
MALE-ON-WIRE |
MALE-ON-WIRE |
NO |
159.88 mm2 |
28 AWG |
28 |
.075 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; DIN; UL; VDE |
1.5 mm2 |
COPPER ALLOY |
STRANDED |
THERMOPLASTIC ELASTOMER |
TIN |
NO |
POLYPROPYLENE |
80 Cel |
YES |
DRAG CHAIN FOR LONG DISTANCE |
NO |
-40 Cel |
16 |
6.7 mm |
3 |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
MIL; NEMA |
COPPER |
STRANDED |
.077 ohm |
SILVER |
YES |
PTFE |
200 Cel |
-60 Cel |
24 |
.97 mm |
1 |
STANDARDS: MIL-W-16878/4 |
30.5 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
26 |
1.3 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
UL |
.23 mm2 |
TINNED COPPER |
STRANDED |
NO |
PVC |
80 Cel |
NO |
NO |
-40 Cel |
24 |
1.42 mm |
1 |
30.5 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; IEC; UL |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.053 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
22 |
1.575 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
.053 ohm |
POLYVINYL CHLORIDE |
105 Cel |
-40 Cel |
22 |
1.575 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
|||||||||||||||||||||||
Weico Wire & Cable |
WIRE AND CABLE |
600 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
8 |
6.731 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
133X29 |
||||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
600 V |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
8 |
6.731 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
133X29 |
||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
150 V |
NO |
CUL; UL |
.0509 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
THERMOPLASTIC ELASTOMER |
105 Cel |
NO |
NO |
-40 Cel |
30 |
10 |
DIAMETER OF INDIVIDUAL CONDUCTOR IS 0.64 MM |
30.48 mm |
FLAT CABLE |
7X38 |
|||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL; UL |
COPPER |
STRANDED |
POLYVINYL CHLORIDE |
TIN |
POLYVINYL CHLORIDE |
80 Cel |
-20 Cel |
28 |
.33 mm |
26 |
3M |
FLAT CABLE |
7X36 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
20000 V |
NO |
.518 mm2 |
COPPER ALLOY |
STRANDED |
.037 ohm |
TIN |
SILICONE RUBBER |
150 Cel |
-40 Cel |
20 |
3.48 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
10X30 |
|||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; HAR; UL |
1.5 mm2 |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
105 Cel |
CABLING |
-40 Cel |
16 |
3.4 mm |
OIL RESISTANT, FLAME RESISTANT |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Belden |
CABLE ASSEMBLY |
M12 3P MALE |
M8 3P FEMALE |
60 V |
4 A |
NO |
CUL; UL |
.34 mm2 |
COPPER ALLOY |
PUR |
NO |
PP |
80 Cel |
NO |
NO |
-50 Cel |
4.3 mm |
3 |
4 mm |
||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.62 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
20 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
SPEC 55 |
-65 Cel |
20 |
1.27 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.62 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
20 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
SPEC 55 |
-65 Cel |
20 |
1.27 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL, NEMA |
.518 mm2 |
COPPER ALLOY |
STRANDED |
.029 ohm |
SILVER |
YES |
POLYTETRAFLUOROETHYLENE |
200 Cel |
ELECTRONIC, MEDICAL, MILITARY |
-60 Cel |
20 |
1.47 mm |
1 |
STANDARD: MIL-DTL-16878/4 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL, NEMA |
1.309 mm2 |
COPPER ALLOY |
STRANDED |
.014 ohm |
SILVER |
YES |
POLYTETRAFLUOROETHYLENE |
200 Cel |
ELECTRONIC, MEDICAL, MILITARY |
-60 Cel |
16 |
2.03 mm |
1 |
STANDARD: MIL-DTL-16878/4 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X29 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL; VDE |
5.261 mm2 |
BARE COPPER |
STRANDED |
POLYVINYLCHLORIDE |
.003 ohm |
POLYVINYLCHLORIDE |
90 Cel |
-40 Cel |
10 |
10.06 mm |
3 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
105X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
.823 mm2 |
COPPER ALLOY |
STRANDED |
.023 ohm |
TIN |
NO |
POLYPHENYLENE ETHER |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.7 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
5.261 mm2 |
COPPER ALLOY |
STRANDED |
.004 ohm |
TIN |
NO |
POLYPHENYLENE ETHER |
105 Cel |
NO |
NO |
-40 Cel |
10 |
3.66 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
105X30 |
||||||||||||||||||
|
Wurth Elektronik |
WIRE AND CABLE |
60 V |
.5 A |
NO |
CUL; UL |
COPPER ALLOY |
FLAT |
1.4 ohm |
TIN |
NO |
PET |
105 Cel |
NO |
NO |
-30 Cel |
24 |
.05 mm |
FLAT CABLE |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; MIL; UL |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
YES |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-55 Cel |
14 |
2.62 mm |
1 |
STANDARD: MIL-W-16878E |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X.0147 |
|||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
.009 ohm |
TIN |
POLYETHYLENE |
125 Cel |
-55 Cel |
14 |
3.51 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
41X30 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
NO |
UL |
COPPER |
STRANDED |
SILVER |
TFE |
24 |
1.118 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.