Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL; UL |
COPPER |
STRANDED |
SILVER |
YES |
TFE |
200 Cel |
ELECTRONIC, MEDICAL, MILITARY |
-60 Cel |
26 |
1.04 mm |
1 |
STANDARD: MIL-W-16878E, FLAME RESISTANT |
30.5 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL; UL |
COPPER |
STRANDED |
SILVER |
YES |
TFE |
200 Cel |
ELECTRONIC, MEDICAL, MILITARY |
-60 Cel |
22 |
1.27 mm |
1 |
STANDARD: MIL-W-16878E, FLAME RESISTANT |
30.5 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
UL |
COPPER |
SOLID |
SILVER |
POLYVINYLIDENE FLUORIDE |
125 Cel |
-40 Cel |
28 |
.58 mm |
1 |
305 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
5 A |
NO |
CEC; CUL; NEC; UL |
.823 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.021 ohm |
NO |
POLYVINYL CHLORIDE |
75 Cel |
NO |
INTERCOM/PA SYSTEMS AND SOUND/AUDIO SYSTEMS |
NO |
0 Cel |
18 |
3.911 mm |
2 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
7X26 |
||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.326 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.053 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
22 |
4.5 mm |
2 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
7X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
NO |
POLYPHENYLENE ETHER |
105 Cel |
NO |
NO |
-40 Cel |
26 |
.97 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
1.309 mm2 |
COPPER ALLOY |
STRANDED |
.014 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-55 Cel |
16 |
2.24 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X.0117 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.518 mm2 |
COPPER ALLOY |
STRANDED |
POLYPHENYLENE ETHER |
.031 ohm |
TIN |
POLYPHENYLENE ETHER |
80 Cel |
-40 Cel |
20 |
5.64 mm |
4 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
13.302 mm2 |
COPPER ALLOY |
STRANDED |
.001 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
6 |
8.534 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
133X27 |
||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
6.5 A |
NO |
UL |
COPPER |
STRANDED |
.03 ohm |
SILVER |
TFE |
200 Cel |
-70 Cel |
20 |
1.473 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
2.3 A |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.048 ohm |
PP |
75 Cel |
-20 Cel |
22 |
4.064 mm |
4 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
20 A |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
18 |
2.794 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
20 A |
NO |
CSA; UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
18 |
2.794 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
2.2 A |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.059 ohm |
POLYVINYL CHLORIDE |
80 Cel |
-30 Cel |
24 |
3.962 mm |
2 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||
|
Belden |
CABLE ASSEMBLY |
M12 MALE |
M12 FEMALE |
60 V |
4 A |
NO |
CUL; UL |
.5 mm2 |
COPPER ALLOY |
PUR |
NO |
PP |
NO |
NO |
5.4 mm |
5 |
30 mm |
||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
32 |
.178 mm |
FLAT CABLE |
|||||||||||||||||||
J S T Mfg |
CABLE ASSEMBLY |
SR CONNECTOR |
SR CONNECTOR |
50 V |
.7 A |
NO |
UL |
30 |
.152 mm |
|||||||||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL, UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
105 Cel |
-20 Cel |
28 |
15 |
FLAT FLEXIBLE CABLE |
7X36 |
||||||||||||||||||||||||||
Nexans Sa |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
SILVER |
YES |
EXTRUDED PTFE |
200 Cel |
ELECTRICAL AND ELECTRONIC COMPONENTS |
-65 Cel |
26 |
1 |
STANDARD: MIL-W-16878/4 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
Nexans Sa |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
SILVER |
YES |
EXTRUDED PTFE |
200 Cel |
ELECTRICAL AND ELECTRONIC COMPONENTS |
-65 Cel |
20 |
1 |
STANDARD: MIL-W-16878/4 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
Standard Wire & Cable |
WIRE AND CABLE |
600 V |
NO |
MIL; NEMA |
COPPER |
STRANDED |
SILVER |
YES |
PTFE |
200 Cel |
20 |
1 |
STANDARD: MIL-W-16878/4 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||||
Carlisle Interconnect Technologies |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
.126 ohm |
SILVER |
YES |
EXTRUDED PTFE |
200 Cel |
NO |
NO |
-55 Cel |
26 |
1.09 mm |
1 |
STANDARD: MIL-W-16878 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||
Carlisle Interconnect Technologies |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
.03 ohm |
SILVER |
YES |
EXTRUDED PTFE |
200 Cel |
NO |
NO |
-55 Cel |
20 |
1.57 mm |
1 |
STANDARD: MIL-W-16878 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
NO |
TINNED COPPER |
FEP |
30 |
4.99 mm |
|||||||||||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
2.9 A |
NO |
.05 mm2 |
COPPER ALLOY |
TIN |
NO |
FLUORINATED ETHYLENE PROPYLENE |
125 Cel |
NO |
NO |
-40 Cel |
30 |
CABLE ASSEMBLY |
|||||||||||||||||||||||||
|
Moxa |
CABLE ASSEMBLY |
USB |
NO |
||||||||||||||||||||||||||||||||||||
Molex |
WIRE AND CABLE |
60 V |
.35 A |
NO |
UL |
.01 mm2 |
COPPER ALLOY |
FLAT |
2.2 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
37 |
35 |
FLAME RESISITANT |
.03 mm |
FLAT CABLE |
|||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.205 mm2 |
COPPER ALLOY |
STRANDED |
.078 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
24 |
1.14 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.009 ohm |
TIN |
POLYVINYLCHLORIDE |
80 Cel |
-20 Cel |
14 |
7.42 mm |
3 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
41X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
2.081 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.009 ohm |
TIN |
POLYVINYLCHLORIDE |
80 Cel |
-20 Cel |
14 |
7.42 mm |
3 |
30.48 mm |
COMMUNICATION AND CONTROL CABLE |
41X30 |
|||||||||||||||||||||
|
Amphenol |
WIRE AND CABLE |
300 V |
1 A |
NO |
CSA, UL |
TINNED COPPER |
POLYVINYL CHLORIDE |
105 Cel |
28 |
34 |
FLAT RIBBON CABLE |
7X36 |
|||||||||||||||||||||||||||
Amphenol |
WIRE AND CABLE |
300 V |
1 A |
NO |
CSA, UL |
TINNED COPPER |
POLYVINYL CHLORIDE |
105 Cel |
28 |
60 |
FLAT RIBBON CABLE |
7X36 |
||||||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
2.08 mm2 |
BARE COPPER |
STRANDED |
CHLORINATED POLYETHYLENE |
.009 ohm |
NEOPRENE |
90 Cel |
-40 Cel |
14 |
13.97 mm |
3 |
76.2 mm |
COMMUNICATION CABLE |
41X30 |
|||||||||||||||||||||
|
Phoenix Contact |
CABLE ASSEMBLY |
IDC/FLK SOCKET |
IDC/FLK SOCKET |
60 V |
1 A |
NO |
CUL; UL |
.14 mm2 |
COPPER |
STRANDED |
SEMI-RIGID POLYVINYL CHLORIDE |
.145 ohm |
TIN |
NO |
70 Cel |
NO |
NO |
-40 Cel |
26 |
9.9 mm |
40 |
1 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||
|
Molex |
CABLE ASSEMBLY |
MICRO-FIT 3.0 |
MICRO-FIT 3.0 |
300 V |
NO |
UL |
POWER |
20 |
5.5 mm |
MICRO-FIT 3.0 |
|||||||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
.081 mm2 |
COPPER ALLOY |
STRANDED |
.19 ohm |
SILVER |
POLYTETRAFLUOROETHYLENE |
200 Cel |
-60 Cel |
28 |
.69 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X40 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
MIL, NEMA |
.081 mm2 |
COPPER ALLOY |
STRANDED |
.197 ohm |
SILVER |
YES |
POLYTETRAFLUOROETHYLENE |
200 Cel |
NO |
NO |
-60 Cel |
28 |
.69 mm |
1 |
STANDARD: MIL-W-16878/6 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X36 |
|||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
1.31 mm2 |
COPPER ALLOY |
SOLID |
.014 ohm |
TIN |
NO |
200 Cel |
NO |
NO |
0 Cel |
16 |
1.295 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
1.309 mm2 |
COPPER ALLOY |
STRANDED |
.014 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
16 |
2.34 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
26X30 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
3.309 mm2 |
COPPER ALLOY |
STRANDED |
.006 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
12 |
3.99 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
65X30 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
5.261 mm2 |
COPPER ALLOY |
STRANDED |
.004 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
10 |
4.67 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
105X30 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
5.261 mm2 |
COPPER ALLOY |
STRANDED |
.004 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
10 |
4.67 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
105X30 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.053 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-10 Cel |
22 |
1.27 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
NO |
-20 Cel |
28 |
16 |
3M, DIAMETER OF INDIVIDUAL CONDUCTOR IS 1.07 MM |
FLAT CABLE |
7X36 |
||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL, UL |
COPPER ALLOY |
STRANDED |
SILVER |
POLYVINYL CHLORIDE |
105 Cel |
-20 Cel |
28 |
26 |
FLAT FLEXIBLE CABLE |
19X40 |
|||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
600 V |
NO |
.96 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
18 AWG |
150 Cel |
GENERAL PURPOSE, LIGHTWEIGHT |
SPEC 44 |
-65 Cel |
18 |
1.65 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL, NEMA, UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
.197 ohm |
SILVER |
YES |
POLYTETRAFLUOROETHYLENE |
200 Cel |
NO |
ELECTRONIC, MEDICAL, MILITARY |
NO |
-60 Cel |
28 |
.89 mm |
1 |
STANDARD: MIL-W-16878/4 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X36 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.