Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Belden |
WIRE AND CABLE |
NO |
UL |
COPPER |
STRANDED |
SILVER |
TFE |
24 |
1.118 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X36 |
|||||||||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
600 V |
4.5 A |
NO |
MIL, NEMA, UL |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.05 ohm |
SILVER |
YES |
TETRAFLUOROETHYLENE |
200 Cel |
NO |
NO |
-70 Cel |
22 |
1.27 mm |
1 |
STANDARD: MIL-W-16878/4 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X30 |
||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.326 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.051 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-10 Cel |
22 |
6.6 mm |
7 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
|||||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
2.1 A |
NO |
CEC; CPR; CSA; CUL; NEC; UL |
TINNED COPPER |
STRANDED |
PVC |
.051 ohm |
NO |
PVC |
80 Cel |
NO |
NO |
-20 Cel |
22 |
5.44 mm |
7 |
COMMUNICATION AND CONTROL CABLE |
7X30 |
|||||||||||||||||||
|
Belden |
WIRE AND CABLE |
300 V |
1.75 A |
NO |
UL |
TINNED COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.082 ohm |
POLYVINYL CHLORIDE |
80 Cel |
-30 Cel |
24 |
6.198 mm |
10 |
FLEXIBLE CORD AND FIXTURE WIRE |
7X32 |
||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
37 |
.254 mm |
FLAT CABLE |
|||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
SAE-AS22759/16 |
1.309 mm2 |
COPPER ALLOY |
STRANDED |
.015 ohm |
TIN |
NO |
ETHYLENE TETRAFLUOROETHYLENE |
150 Cel |
NO |
NO |
-55 Cel |
16 |
2.01 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X29 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.823 mm2 |
COPPER ALLOY |
STRANDED |
.019 ohm |
TIN |
ETHYLENE TETRAFLUOROETHYLENE |
150 Cel |
-55 Cel |
18 |
1.8 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.823 mm2 |
COPPER ALLOY |
STRANDED |
.019 ohm |
TIN |
ETHYLENE TETRAFLUOROETHYLENE |
150 Cel |
-55 Cel |
18 |
1.8 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X30 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.05 ohm |
TIN |
NO |
ETHYLENE TETRAFLUOROETHYLENE |
150 Cel |
NO |
NO |
-55 Cel |
22 |
1.32 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
|||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
150 V |
NO |
CUL; UL |
.05 mm2 |
COPPER |
SOLID |
TIN |
NO |
THERMOPLASTIC ELASTOMER |
105 Cel |
NO |
NO |
-40 Cel |
30 |
.64 mm |
80 |
30.48 mm |
FLAT CABLE |
1X30 |
|||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
SOCKET |
SOCKET |
2.3 A |
NO |
UL |
.0509 mm2 |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
HIGH RELIABILITY |
NO |
-40 Cel |
30 |
50 |
TIGER EYE |
.305 mm |
FLAT CABLE |
7X38 |
|||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
Defense Logistics Agency |
WIRE AND CABLE |
600 V |
NO |
MIL |
COPPER |
STRANDED |
TIN |
EXTRUDED ETFE |
150 Cel |
26 |
.032 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
SOCKET |
SOCKET |
375 V |
4 A |
NO |
UL |
105 Cel |
-10 Cel |
24 |
8 |
.08 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
NO |
PBT |
26 |
.06 mm |
||||||||||||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
350 V |
2.6 A |
NO |
UL |
.205 mm2 |
TINNED COPPER |
STRANDED |
.085 ohm |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
NO |
-10 Cel |
24 |
1.118 mm |
.049 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||
Tag-connect |
CABLE ASSEMBLY |
14P PLUG |
IDC FEMALE |
NO |
NO |
NO |
NO |
14 |
PLUG-OF-NAILS |
203.2 mm |
FLAT CABLE |
|||||||||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
FEMALE CONNECTOR |
FEMALE CONNECTOR |
2.8 A |
NO |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
POLYVINYL CHLORIDE |
105 Cel |
-40 Cel |
28 |
20 |
.102 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||||||
|
Samtec |
CABLE ASSEMBLY |
SOCKET |
SOCKET |
300 V |
2.8 A |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
28 |
34 |
.254 mm |
FLAT CABLE |
7X36 |
|||||||||||||||||
|
Panduit |
WIRE AND CABLE |
NO |
IEC; UL |
.205 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
GOLD |
NO |
60 Cel |
NO |
YES |
-10 Cel |
24 |
5.7 mm |
8 |
4.27 mm |
COMMUNICATION CABLE |
|||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
150 V |
NO |
UL |
COPPER |
STRANDED |
SILVER |
EXTRUDED FEP |
150 Cel |
30 |
60 |
DIAMETER OF INDIVIDUAL CONDUCTOR IS 0.61 MM |
FLAT FLEXIBLE CABLE |
7X38 |
|||||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
300 V |
1.5 A |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
FEP |
SILVER |
NO |
EXTRUDED FEP |
200 Cel |
NO |
NO |
-65 Cel |
28 |
10 |
DIAMETER OF INDIVIDUAL CONDUCTOR IS 0.74 MM |
FLAT CABLE |
7X36 |
||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; UL |
1.309 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.014 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
80 Cel |
NO |
NO |
-20 Cel |
16 |
10.49 mm |
4 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
19X.0117 |
|||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.5 A |
NO |
UL |
.03 mm2 |
COPPER ALLOY |
FLAT |
.73 ohm |
GOLD |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
32 |
24 |
.102 mm |
FLAT CABLE |
|||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; EAC; IPA; VDE |
.75 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
POLYVINYL CHLORIDE |
80 Cel |
FLEXIBLE USE FOR MEDIUM MECHANICAL, STRESSES WITH FREE MOVES |
-40 Cel |
19 |
8.3 mm |
7 |
CONTROL CABLE |
|||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
50 V |
.2 A |
NO |
COPPER ALLOY |
FLAT |
6.8 ohm |
GOLD |
NO |
POLYAMIDE |
105 Cel |
NO |
NO |
-40 Cel |
45 |
.051 mm |
FLAT CABLE |
||||||||||||||||||||||
|
Molex |
WIRE AND CABLE |
60 V |
.35 A |
NO |
UL |
.01 mm2 |
COPPER ALLOY |
FLAT |
2.2 ohm |
TIN |
NO |
POLYESTER |
105 Cel |
NO |
NO |
-40 Cel |
37 |
46 |
FLAME RESISITANT |
.305 mm |
FLAT CABLE |
||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
4 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
12 |
4.9 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
512X0.1 |
||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EN; HAR; IEC; VDE |
1.5 mm2 |
BARE COPPER |
STRANDED |
RUBBER |
RUBBER |
60 Cel |
MEDIUM, MECHANICAL STRESS AND INDUSTRIAL AND AGRICULTURAL |
-25 Cel |
11.9 mm |
3 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL, UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
POLYVINYL CHLORIDE |
105 Cel |
NO |
NO |
-20 Cel |
28 |
34 |
30.48 mm |
FLAT CABLE |
7X36 |
||||||||||||||||||||
|
Volex Plc |
CABLE ASSEMBLY |
CEE 7/7 |
IEC 60320 C13 |
250 V |
10 A |
NO |
CEBEC; DEMKO; FIMKO; IMQ; KEMA; NEMKO; OVE; SEMKO; VDE |
POLYVINYL CHLORIDE |
POWER CABLE |
||||||||||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
MIL |
.518 mm2 |
COPPER ALLOY |
STRANDED |
.033 ohm |
TIN |
YES |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
20 |
1.47 mm |
1 |
STANDARDS: MIL-DTL-16878/1, MIL-W-76 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X28 |
|||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; EAC; HAR; UL; VDE |
1.04 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
POLYVINYL CHLORIDE |
60 Cel |
KITCHENS AND OFFICES, ALSO FOR HOUSEHOLD APPLIANCES |
-40 Cel |
17 |
8.8 mm |
4 |
CONTROL CABLE |
|||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.115 ohm |
SILVER |
POLYTETRAFLUOROETHYLENE |
200 Cel |
-60 Cel |
26 |
.79 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.115 ohm |
SILVER |
POLYTETRAFLUOROETHYLENE |
200 Cel |
-60 Cel |
26 |
.79 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X38 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
250 V |
NO |
.326 mm2 |
COPPER ALLOY |
STRANDED |
.046 ohm |
SILVER |
POLYTETRAFLUOROETHYLENE |
200 Cel |
-60 Cel |
22 |
1.09 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X34 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
.129 mm2 |
COPPER ALLOY |
SOLID |
.144 ohm |
TIN |
NO |
200 Cel |
NO |
NO |
0 Cel |
26 |
.406 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X26 |
|||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
NO |
.205 mm2 |
COPPER ALLOY |
SOLID |
.089 ohm |
TIN |
NO |
200 Cel |
NO |
NO |
0 Cel |
24 |
.508 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1 |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
300 V |
NO |
CE; DIN VDE 0285-525-3-11; DIN EN 50525-3-11 |
1 mm2 |
BARE COPPER |
STRANDED |
POLYETHYLENE |
NO |
POLYETHYLENE |
70 Cel |
YES |
COOKING AND HEATING APPARATUS |
YES |
-40 Cel |
18 |
7.7 mm |
4 |
CONTROL CABLE |
||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
||||||||||||||||||||||
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.