Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
110 mJ |
-55 °C (-67 °F) |
35 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
75 V |
3.15 A |
End Cap |
17.72 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
10 ms |
Rated Breaking Capacity at 75 VDC: 70 A, Pre Arcing Time: Open within 10 ms at 400% Rated Current |
17.72 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
1 A |
End Cap |
5.64 J |
-55 °C (-67 °F) |
Tin |
35 A |
3 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.189 in (4.8 mm) |
e3 |
2AG |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.587 in (14.9 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
3 A |
End Cap |
77 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.177 in (4.5 mm) |
e3 |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
1 A |
End Cap |
1.373 J |
-60 °C (-76 °F) |
Nickel |
10 kA |
2 m |
Pre Arcing Time: Open within 2 m at 200% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; KC; PSE |
125 °C (257 °F) |
Medium |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
100 mA |
End Cap |
55 mJ |
-55 °C (-67 °F) |
Tin |
35 A |
2 m |
0.05 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
End Cap |
760 J |
-55 °C (-67 °F) |
Nickel |
300 A |
Bulk |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 mA |
End Cap |
120 μJ |
-55 °C (-67 °F) |
Matte Tin |
35 A |
313 |
Bulk |
0.25 in (6.35 mm) |
e3 |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2.8 A |
End Cap |
170 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
170 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
32 V |
2.5 A |
End Cap |
351.6 mJ |
-55 °C (-67 °F) |
Matte Tin Over Nickel |
50 A |
Rated Breaking Capacity at 32 VDC: 50 A |
Tape And Reel |
0.125 in (3.18 mm) |
0.06 in (1.52 mm) |
e3 |
0.125 x 0.06 x 0.023 in (3.18 x 1.52 x 0.58 mm) |
0.023 in (0.58 mm) |
CSA; UL |
90 °C (194 °F) |
Very Fast |
||||||||||
IXYS Corporation |
Electric Fuse |
Inline/Holder |
690 V |
690 V |
1 kA |
End Cap |
240 J |
200 kA |
069UR2S |
Rated Breaking Capacity at 690 VDC: 200000 A |
2.362 in (60 mm) |
1.992 in (50.6 mm) |
Indicator |
2.362 x 1.992 x 2.579 in (60 x 50.6 x 65.5 mm) |
2.579 in (65.5 mm) |
DIN; IEC; UL; VDE |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
450 V |
2 A |
End Cap |
17 J |
-55 °C (-67 °F) |
Nickel |
100 A |
Rated Breaking Capacity at 450 VDC: 200 A, Pre-Arcing Time: Open within 10 ms at 1000% Rated Current |
17 |
Bulk |
0.205 in (5.2 mm) |
500 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; PSE; SEMKO |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
10 kA |
12 s |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
40 A |
End Cap |
Silver |
100 kA |
0.406 in (10.3 mm) |
G |
e4 |
480 V |
0.406 x 2.252 in (10.3 x 57.2 mm) |
2.252 in (57.2 mm) |
CSA, UL |
Medium |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
12 KV |
6.3 A |
End Cap |
20 J |
40 kA |
2.5 in (63.5 mm) |
10 in (254 mm) |
BS 2692-1; IEC |
|||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
14.4 KV |
14.4 KV |
175 A |
End Cap |
63 kA |
2.992 in (76 mm) |
23.898 in (607 mm) |
||||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
15.5 KV |
15.5 KV |
65 A |
End Cap |
63 kA |
2.992 in (76 mm) |
23.898 in (607 mm) |
ANSI; UL |
|||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
14.4 KV |
14.4 KV |
3 A |
End Cap |
80 kA |
1.614 in (41 mm) |
17.598 in (447 mm) |
||||||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
14.4 KV |
14.4 KV |
2 A |
End Cap |
63 kA |
1.614 in (41 mm) |
12.913 in (328 mm) |
||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
250 A |
End Cap |
7.75 kJ |
100 kA |
2.913 in (74 mm) |
2.087 in (53 mm) |
Indicator |
2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm) |
2.087 in (53 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
400 A |
End Cap |
29.5 kJ |
100 kA |
3.15 in (80 mm) |
2.087 in (53 mm) |
Indicator |
3.15 x 2.087 x 2.087 in (80 x 53 x 53 mm) |
2.087 in (53 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
700 A |
End Cap |
160 kJ |
100 kA |
3.15 in (80 mm) |
2.402 in (61 mm) |
Indicator |
3.15 x 2.402 x 2.402 in (80 x 61 x 61 mm) |
2.402 in (61 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
400 mA |
End Cap |
1.324 J |
-55 °C (-67 °F) |
35 A |
20 ms |
Pre Arcing Time: Open within 20 ms at 1000% Rated Current |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KTL; SEMKO; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.5 A |
End Cap |
15 J |
-55 °C (-67 °F) |
Nickel |
100 A |
0.177 in (4.5 mm) |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; METI; PSE; UL |
125 °C (257 °F) |
Slow |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
24 KV |
24 KV |
63 A |
End Cap |
3.8 kJ |
50 kA |
3 in (76.2 mm) |
3 x 17.402 in (76.2 x 442 mm) |
17.402 in (442 mm) |
DIN 43625; IEC; VDE |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
10 A |
End Cap |
298 J |
35 A |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
0.25 in (6.35 mm) |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
400 V |
63 A |
End Cap |
12.3 kJ |
50 kA |
Bulk |
0.591 in (15 mm) |
D02 |
0.591 x 1.417 in (15 x 36 mm) |
1.417 in (36 mm) |
DIN 49515; IEC60269 |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
35 A |
End Cap |
2.7 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
60 A |
End Cap |
2.7 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
750 A |
End Cap |
2.7 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
125 V |
5 A |
End Cap |
58 J |
Nickel |
10 kA |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.205 in (5.2 mm) |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; KC; MITI; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
End Cap |
354 J |
Nickel |
1 kA |
Box |
0.25 in (6.35 mm) |
32 V |
0.252 x 1.248 in (6.4 x 31.7 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
6 A |
End Cap |
37.4 J |
Nickel |
200 A |
Box |
0.25 in (6.35 mm) |
250 V |
0.252 x 1.248 in (6.4 x 31.7 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
Nickel |
100 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Time Delay |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
100 mA |
End Cap |
Nickel |
35 A |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 mA |
End Cap |
Nickel |
35 A |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
6 A |
End Cap |
Nickel |
200 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
8 A |
End Cap |
Nickel |
200 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1 in (6.3 x 25.4 mm) |
0.25 x 1.042 in (6.35 x 26.47 mm) |
1 in (25.4 mm) |
CUL |
Fast |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
237.6 J |
Nickel |
63 A |
Box |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; IMQ; MITI/JET; UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
800 mA |
End Cap |
700 mJ |
Silver |
35 A |
Pre Arcing Time: OPEN within 2 MIN at 200% RATED CURRENT |
0.7 |
Box |
0.205 in (5.2 mm) |
e4 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; UL |
Fast |
|||||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
125 V |
5 A |
End Cap |
58 J |
Nickel |
10 kA |
GMC |
Box |
0.205 in (5.2 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CSA; MITI; UL |
Medium Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
12.21 J |
Nickel |
35 A |
2 m |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
70.4 J |
Nickel |
100 A |
2 m |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
|||||||||||||
|
Cooper Electronic Technologies |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
End Cap |
354 J |
1 kA |
MDL |
Box |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Cooper Electronic Technologies |
Electric Fuse |
Inline/Holder |
250 V |
6 A |
End Cap |
37.4 J |
200 A |
MDL |
Box |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
800 mA |
End Cap |
670 mJ |
Nickel |
35 A |
Box |
0.205 in (5.2 mm) |
250 V |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; CUL; IMQ; SEMKO; UL; VDE |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
100 mA |
End Cap |
1.8 mJ |
Silver |
1.5 kA |
0.0018 |
Box |
0.205 in (5.2 mm) |
e4 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CSA; UL |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
114 mJ |
Nickel |
35 A |
0.114 |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CSA; IMQ; SEMKO; UL; VDE |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.