Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
3 A |
End Cap |
4 J |
-40 °C (-40 °F) |
50 kA |
Box |
0.406 in (10.3 mm) |
0.394 x 1.496 in (10 x 38 mm) |
0.409 x 1.516 in (10.4 x 38.5 mm) |
1.496 in (38 mm) |
CCC; CSA; IEC; UL |
90 °C (194 °F) |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.5 KV |
4 A |
End Cap |
15 J |
30 kA |
Bulk |
0.406 in (10.3 mm) |
0.394 x 3.346 in (10 x 85 mm) |
3.346 in (85 mm) |
IEC; UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1.6 A |
End Cap |
1.9 J |
Nickel |
1.5 kA |
Tape And Reel |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; IEC; SEMKO; UL; VDE |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
2 A |
End Cap |
5 J |
20 kA |
4 m |
5 |
Bulk |
0.406 in (10.31 mm) |
0.406 x 2.5 in (10.31 x 63.5 mm) |
2.5 in (63.5 mm) |
CE, TUV, UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
30 A |
End Cap |
3.77 kJ |
50 kA |
Bulk |
0.54 in (13.72 mm) |
GPV |
1.5 KV |
240 s |
0.409 x 3.358 in (10.4 x 85.3 mm) |
3.333 in (84.65 mm) |
CUL |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
170 V |
30 A |
End Cap |
100 kA |
Rated Breaking Capacity at 170 VDC: 100000 A |
0.406 in (10.31 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
250 V |
125 V |
5 A |
End Cap |
88.38 J |
50 A |
4 h |
Rated Breaking Capacity at 125 VDC: 50 A |
88.38 |
Tape And Reel |
0.405 in (10.29 mm) |
0.109 in (2.77 mm) |
250 V |
0.405 x 0.109 x 0.109 in (10.29 x 2.77 x 2.77 mm) |
0.109 in (2.77 mm) |
CSA; UL |
Time Delay |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
300 mA |
End Cap |
68.9 mJ |
Tin Lead |
35 A |
4 h |
0.0689 |
0.25 in (6.35 mm) |
Supplemental |
e0 |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
|||||||||||
|
Bourns |
Electric Fuse |
Surface Mount |
600 V |
1.25 A |
End Cap |
14 J |
-55 °C (-67 °F) |
Tin with Nickel barrier |
Tape And Reel |
0.38 in (9.65 mm) |
0.12 in (3.05 mm) |
e3 |
600 V |
0.38 x 0.12 x 0.12 in (9.65 x 3.05 x 3.05 mm) |
0.12 in (3.05 mm) |
UL |
125 °C (257 °F) |
|||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
10 A |
End Cap |
-60 °C (-76 °F) |
0.866 in (22 mm) |
GG |
500 V |
1.969 in (50 mm) |
85 °C (185 °F) |
||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
16 A |
End Cap |
-60 °C (-76 °F) |
0.866 in (22 mm) |
GG |
500 V |
1.969 in (50 mm) |
85 °C (185 °F) |
||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
6 A |
End Cap |
-60 °C (-76 °F) |
0.433 in (11 mm) |
1.417 in (36 mm) |
EAC |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
2 A |
End Cap |
0.866 in (22 mm) |
500 V |
1.969 in (50 mm) |
|||||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
63 A |
End Cap |
-60 °C (-76 °F) |
0.591 in (15 mm) |
400 V |
1.417 in (36 mm) |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
25 A |
End Cap |
-60 °C (-76 °F) |
0.591 in (15 mm) |
1.417 in (36 mm) |
EAC |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
10 A |
End Cap |
-60 °C (-76 °F) |
0.433 in (11 mm) |
1.417 in (36 mm) |
EAC |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
50 A |
End Cap |
-60 °C (-76 °F) |
0.591 in (15 mm) |
400 V |
1.417 in (36 mm) |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
4 A |
End Cap |
-60 °C (-76 °F) |
0.433 in (11 mm) |
1.417 in (36 mm) |
EAC |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
16 A |
End Cap |
-60 °C (-76 °F) |
0.433 in (11 mm) |
400 V |
1.417 in (36 mm) |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
400 V |
20 A |
End Cap |
-60 °C (-76 °F) |
0.591 in (15 mm) |
400 V |
1.417 in (36 mm) |
85 °C (185 °F) |
|||||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
25 A |
End Cap |
-60 °C (-76 °F) |
0.866 in (22 mm) |
GG |
500 V |
1.969 in (50 mm) |
85 °C (185 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
5 A |
End Cap |
267 J |
-55 °C (-67 °F) |
Tin |
400 A |
4 h |
267 |
Bulk |
0.177 in (4.5 mm) |
e3 |
125 V |
2AG |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
45 A |
End Cap |
10 kA |
0.811 in (20.6 mm) |
0.811 x 3 in (20.6 x 76.2 mm) |
3 in (76.2 mm) |
CSA; UL |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
1.25 A |
End Cap |
10 kA |
0.205 in (5.2 mm) |
Supplemental |
125 V |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE, CSA, PSE, UL |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
80 mA |
End Cap |
850 μJ |
-55 °C (-67 °F) |
Matte Tin |
35 A |
217 |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KTL; SEMKO; UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 A |
End Cap |
200 kA |
Bulk |
0.811 in (20.6 mm) |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; QPL; UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3 A |
End Cap |
27 J |
0.197 in (5 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CSA; MITI; UL |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
12 A |
End Cap |
234.6 J |
Nickel |
312P |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
160 mA |
End Cap |
110 mJ |
-25 °C (-13 °F) |
Nickel |
80 A |
Bulk |
0.205 in (5.2 mm) |
250 V |
5 ms |
Indicator |
0.205 x 0.984 in (5.2 x 25 mm) |
0.984 in (25 mm) |
DIN 41577 |
70 °C (158 °F) |
Medium |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 A |
End Cap |
200 kA |
0.811 in (20.6 mm) |
J |
600 V |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; QPL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
6.3 A |
End Cap |
151.54 J |
-60 °C (-76 °F) |
Nickel |
300 A |
2 m |
Pre Arcing Time: Open within 2 m at 200% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; KC; PSE |
125 °C (257 °F) |
Medium |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
5.64 J |
-55 °C (-67 °F) |
Tin |
35 A |
Bulk |
0.177 in (4.5 mm) |
e3 |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; METI; PSE; UL |
125 °C (257 °F) |
Slow |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
1.25 A |
End Cap |
-55 °C (-67 °F) |
10 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
2 A |
End Cap |
Bulk |
0.25 in (6.35 mm) |
32 V |
8AG |
1 in (25.4 mm) |
Normal |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
15 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
7 A |
End Cap |
13.92 J |
-55 °C (-67 °F) |
Gold |
50 A |
Rated Breaking Capacity at 125 VDC: 50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
62 mA |
End Cap |
100 μJ |
-65 °C (-85 °F) |
Silver |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.109 in (2.77 mm) |
e4 |
5 s |
0.24 x 0.109 x 0.109 in (6.1 x 2.77 x 2.77 mm) |
0.109 in (2.77 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
25 A |
End Cap |
Nickel |
593 |
|||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
4.5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
8 A |
End Cap |
656 mJ |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 mA |
End Cap |
57 mJ |
-25 °C (-13 °F) |
80 A |
5 ms |
Pre Arcing Time: Open within 5 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
Indicator |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; UL |
70 °C (158 °F) |
Medium Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
3 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
20 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
250 mA |
End Cap |
200 kA |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Lag |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
1.16 J |
-55 °C (-67 °F) |
Nickel |
35 A |
229 |
Bulk |
0.177 in (4.5 mm) |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Slow |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
150 A |
End Cap |
60 kA |
15NLE2-150E |
6.378 in (162 mm) |
6.378 x 23.874 in (162 x 606.4 mm) |
23.874 in (606.4 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 mA |
End Cap |
35.5 mJ |
-55 °C (-67 °F) |
35 A |
Bulk |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Fast |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
350 A |
End Cap |
80 kA |
Hermitically Sealed Part Number |
9.75 in (247.65 mm) |
9.75 x 15.875 in (247.65 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.