End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

175E-2C-5.5S

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

175 A

End Cap

80 kA

175E-2C-5.5

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

3401600002

Littelfuse

Electric Fuse

Inline/Holder

250 V

6 A

End Cap

80 J

-25 °C (-13 °F)

200 A

Bulk

0.248 in (6.3 mm)

120 s

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CSA; UL

70 °C (158 °F)

Very Fast

225004DRT1

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

9.4 J

10 kA

225

Tape And Reel

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

0235.250P

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

16.6 mJ

-55 °C (-67 °F)

Nickel

35 A

235

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; UL

125 °C (257 °F)

Fast

0213.200P

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

225 mJ

-55 °C (-67 °F)

Nickel

35 A

213P

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

FLQ015R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

15 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0362010.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

10 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

8AG

1 in (25.4 mm)

Normal

0481003.HXM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

3 A

End Cap

25 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

07945810194

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

141 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

LA15QS2500-128IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

2.5 kA

End Cap

3.2 kJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

3 in (76.2 mm)

3 x 1.63 in (76.2 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

R452.750MRL

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

750 mA

End Cap

904 mJ

-55 °C (-67 °F)

Gold

50 A

452

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; UL

125 °C (257 °F)

Slow

2323.15

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

21.958 J

-55 °C (-67 °F)

Tin

100 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE

125 °C (257 °F)

Medium

NLN001

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1 A

End Cap

50 kA

Rated Breaking Capacity at 250 VDC; 20000

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

7945816037

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.5 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

1950160002

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

220 mJ

-25 °C (-13 °F)

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CCEE; CUL; DIN; IEC; IMQ; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

LA130URD72TTI0550

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

550 A

End Cap

68 J

100 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 2.854 in (60 x 60 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

048107.5HP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

121 J

-55 °C (-67 °F)

Tin

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

SPXC002.L

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

2 A

End Cap

1.55 J

15 kA

4 m

Bulk

0.406 in (10.31 mm)

0.394 x 2.244 in (10 x 57 mm)

2.252 in (57.2 mm)

CE; UL

Fast

313.300

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

300 mA

End Cap

730 mJ

-55 °C (-67 °F)

Tin/Lead

35 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

0.73

0.25 in (6.35 mm)

Supplemental

e0

250 V

3.135 Ω

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Slow

023502.5MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

5.445 J

-55 °C (-67 °F)

100 A

5 s

Bulk

0.197 in (5 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Fast

AGC30CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

30 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

AGA2BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

2 A

End Cap

0.25 in (6.35 mm)

32 V

1AG

0.625 in (15.875 mm)

0506016MXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

16 A

End Cap

61 J

-55 °C (-67 °F)

Nickel

10 kA

61

Bulk

0.25 in (6.35 mm)

600 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Fast

217002

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

2 A

End Cap

5.726 J

-55 °C (-67 °F)

Nickel

35 A

5.73

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

250 V

41.6 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; IEC; PSE; SEMKO; VDE

125 °C (257 °F)

Fast

225003M

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

4.62 J

100 A

225

Bulk

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

3430500000

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

4.2 J

-25 °C (-13 °F)

35 A

Bulk

0.248 in (6.3 mm)

5 s

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CSA; UL

70 °C (158 °F)

Time Delay

LCN200ED

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

200 A

End Cap

60 kA

LCN

6.38 in (162.05 mm)

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

2010032002

Littelfuse

Electric Fuse

Inline/Holder

250 V

32 mA

End Cap

5 mJ

-25 °C (-13 °F)

Matte Tin

80 A

Bulk

0.205 in (5.2 mm)

e3

250 V

5 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

DIN 41571; UL

70 °C (158 °F)

Medium Time Lag

0312.300HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

300 mA

End Cap

68.9 mJ

-55 °C (-67 °F)

Nickel

35 A

5 s

0.0689

Tape And Reel

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Fast

0233001.XP

Littelfuse

Electric Fuse

Inline/Holder

125 V

1 A

End Cap

2.03 J

-55 °C (-67 °F)

Matte Tin

10 kA

233

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Medium

5NLE-50EL

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

50 A

End Cap

80 kA

5NLE-50E

3 in (76.2 mm)

3 x 17.874 in (76.2 x 454 mm)

17.874 in (454 mm)

0455.500

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

500 mA

End Cap

143 mJ

-55 °C (-67 °F)

Tin Lead

50 A

455

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e0

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

IEC; UL

125 °C (257 °F)

Fast

390-18R-2C-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

390 A

End Cap

1.44 kA

15 s

6.382 in (162.1 mm)

Striker

6.38 x 15.875 in (162.05 x 403.23 mm)

15.874 in (403.2 mm)

40 °C (104 °F)

Medium

216.100PMRET1

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

4.5 mJ

-55 °C (-67 °F)

Matte Tin

1.5 kA

216P

Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0481.500VM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

500 mA

End Cap

490 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

3261.5MHXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1.5 A

End Cap

40.1 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0233007.MXBP

Littelfuse

Electric Fuse

Inline/Holder

125 V

7 A

End Cap

157.31 J

-55 °C (-67 °F)

Matte Tin

10 kA

Bulk

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; UL

125 °C (257 °F)

Medium

0388009.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

9 A

End Cap

-55 °C (-67 °F)

Tin

100 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; PSE

125 °C (257 °F)

JLLS035.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.992 in (25.2 mm)

600 V

1.563 in (39.7 mm)

CE; CSA; UL

Fast

307001H

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

Normal

0312002MX

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

5.2 J

-55 °C (-67 °F)

Tin

100 A

312

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

FLNR025

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

0487015.MXP

Littelfuse

Electric Fuse

Inline/Holder

420 V

420 V

15 A

End Cap

190 J

-60 °C (-76 °F)

200 A

30 ms

Rated Breaking Capacity at 420 VDC: 300 A

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CUL; TUV; UL

125 °C (257 °F)

Fast

F03A250V1AS

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1 A

End Cap

Silver

35 A

0.25 in (6.35 mm)

e4

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

MIL-PRF-15160/3

0481010.VX

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

10 A

End Cap

380.3 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481004.VM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

4 A

End Cap

36 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

3260.6MMXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 mA

End Cap

3.9 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

LCL18RW

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

390 A

End Cap

1.5 kA

LCL

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.