End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BLN5

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

592.300

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

300 mA

End Cap

Nickel

592

350E-3C-8.25L

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

20 A

End Cap

80 kA

350E-3C-8.25

9.748 in (247.6 mm)

9.748 x 15.874 in (247.6 x 403.2 mm)

15.874 in (403.2 mm)

0218.032MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

32 mA

End Cap

11 mJ

-55 °C (-67 °F)

Tin

35 A

Bulk

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0235007.P

Littelfuse

Electric Fuse

Inline/Holder

125 V

7 A

End Cap

64.815 J

-55 °C (-67 °F)

Nickel

10 kA

235

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; UL

125 °C (257 °F)

Fast

0213.315P

Littelfuse

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

1.14 J

-55 °C (-67 °F)

Nickel

35 A

213P

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

IDSR.400

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

400 mA

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLNR040

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

40 A

End Cap

200 kA

KLNR

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

3 in (76.2 mm)

CSA; UL

Fast

312.187P

Littelfuse

Electric Fuse

Inline/Holder

250 V

187 mA

End Cap

12.8 mJ

Nickel

35 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Fast

023903.2MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.2 A

End Cap

128.05 J

-55 °C (-67 °F)

Tin

100 A

4 h

128.05

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; UL

125 °C (257 °F)

Time Lag

0235003.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

8.395 J

-55 °C (-67 °F)

Nickel

100 A

235

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

593012

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

12 A

End Cap

Nickel

593

022903.5P

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

3.5 A

End Cap

110 J

-55 °C (-67 °F)

Nickel

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

0.177 in (4.5 mm)

Indicator

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

150E2C8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 15.875 in (162.05 x 403.23 mm)

15.874 in (403.2 mm)

Medium

LA120X20-1

Littelfuse

Electric Fuse

Inline/Holder

1.2 KV

1 KV

20 A

End Cap

3.7 kJ

100 kA

Rated Breaking Capacity at 1000 VDC: 100000 A

0.811 in (20.6 mm)

1.2 KV

0.811 x 4.606 in (20.6 x 117 mm)

4.606 in (117 mm)

Very Fast

048107.5VMP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

121 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

3260.2MMXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

213 mJ

-55 °C (-67 °F)

Matte Tin

100 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

JLS006

Littelfuse

Electric Fuse

Inline/Holder

600 V

6 A

End Cap

200 kA

Bulk

0.811 in (20.6 mm)

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; QPL; UL

Fast

048107.5

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

42.8 J

-55 °C (-67 °F)

Tin/Lead

300 A

481

Rated Breaking Capacity at 125 VDC: 300 A

Box

e0

Alarm

CSA; UL

125 °C (257 °F)

0233010.MXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

10 A

End Cap

274.115 J

-55 °C (-67 °F)

Nickel

10 kA

400 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

0481005V

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

5 A

End Cap

26.2 J

-55 °C (-67 °F)

Tin

300 A

Rated Breaking Capacity at 125 VDC: 200 A

Bulk

e3

Alarm

CSA; UL

90 °C (194 °F)

0232004

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

38.75 J

-55 °C (-67 °F)

Nickel

100 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

KTL; METI; PSE

125 °C (257 °F)

Medium

KLDR02.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

21.28 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0332001.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1 A

End Cap

146 mJ

-55 °C (-67 °F)

100 A

1 s

0.1

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CUL; PSE; UL

125 °C (257 °F)

Very Fast

0481.650V

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

650 mA

End Cap

723 mJ

-55 °C (-67 °F)

Tin

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

150E2C2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

150 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 10.875 in (162.05 x 276.23 mm)

10.874 in (276.2 mm)

Medium

0233004.MXBP

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

51.61 J

-55 °C (-67 °F)

Nickel

10 kA

Bulk

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Medium

0217003.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

-55 °C (-67 °F)

Nickel

35 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Very Fast

0362007.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

7 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

8AG

1 in (25.4 mm)

Normal

SLC025

Littelfuse

Electric Fuse

Inline/Holder

480 V

25 A

End Cap

100 kA

0.406 in (10.3 mm)

0.406 x 1.626 in (10.3 x 41.3 mm)

1.626 in (41.3 mm)

CSA; UL

Medium Time Delay

3268MMXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

67.1 J

-55 °C (-67 °F)

Matte Tin

400 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

235.250

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

17 mJ

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; UL

125 °C (257 °F)

Fast

1960500000

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

4.4 J

-25 °C (-13 °F)

150 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CUL; IEC; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

31202.5P

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

9.54 J

Nickel

35 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Fast

225002DRT1

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

1.5 J

100 A

225

Tape And Reel

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

KLKD12

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

12 A

End Cap

100 kA

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

LLNRK.600

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

80E-1C-5.5L

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

80 A

End Cap

80 kA

80E-1C-5.5

3 in (76.2 mm)

3 x 15.874 in (76.2 x 403.2 mm)

15.874 in (403.2 mm)

LLSRK035ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

Indicator

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

217002XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

5.88 J

-55 °C (-67 °F)

Matte Tin

35 A

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL

125 °C (257 °F)

Fast

KLDR1.25HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

436.7 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

048103.5HM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

3.5 A

End Cap

10.5 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

3267MMXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

7 A

End Cap

47.3 J

-55 °C (-67 °F)

Matte Tin

400 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

LDZ350Z

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

350 A

End Cap

80 kA

LDZ

9.75 in (247.65 mm)

9.75 x 15.875 in (247.65 x 403.23 mm)

15.875 in (403.23 mm)

Medium

L25S15

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

15 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Fast

0SPF004.TXS

Littelfuse

Electric Fuse

Inline/Holder

1 KV

4 A

End Cap

23 J

Silver

20 kA

4 m

Bulk

0.406 in (10.31 mm)

e4

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

0234005.XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

21.2 J

-55 °C (-67 °F)

Nickel

200 A

Pre-Arcing Time: Open within 0.4 s, at 200% Rated Current

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Medium

1941500002

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

35 J

-25 °C (-13 °F)

1.5 kA

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CUL; DIN; IEC; SEMKO; UL; VDE

70 °C (158 °F)

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.