End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

FLSR045ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

45 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

Indicator

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; QPL; UL

Time Delay

59304.5S

Littelfuse

Electric Fuse

Inline/Holder

250 V

4.5 A

End Cap

Silver

0.394 in (10 mm)

e4

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

MIL-PRF-15160

Time Delay

0216.125MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

5.46 mJ

-55 °C (-67 °F)

Tin

1.5 kA

0.0054

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

02163.15MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

6.7 J

-55 °C (-67 °F)

Tin

1.5 kA

6.7

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Fast

150E-2C-5.5S

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

KLKD.200

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

0326.400HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

400 mA

End Cap

1.33 J

-55 °C (-67 °F)

Nickel

100 A

4 h

1.33

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

LGR5

Littelfuse

Electric Fuse

Inline/Holder

300 V

5 A

End Cap

10 kA

0.61 in (15.49 mm)

0.61 x 1.82 in (15.49 x 46.23 mm)

1.82 in (46.23 mm)

CSA; UL

Fast

239002.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

50.586 J

-55 °C (-67 °F)

Tin

100 A

239P

Bulk; Tape And Reel

0.787 in (20 mm)

e3

0.787 x 0.205 in (20 x 5.2 mm)

0.205 in (5.2 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

JTD025

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

03136.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.25 A

End Cap

388 J

-60 °C (-76 °F)

Nickel

200 A

5 s

242

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

650-36R-3C-5.5S

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

650 A

End Cap

2.9 kA

Hermitically Sealed Part Number

9.75 in (247.65 mm)

9.75 x 15.875 in (247.65 x 403.23 mm)

15.875 in (403.23 mm)

Medium

216001

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1 A

End Cap

180 mJ

-55 °C (-67 °F)

Nickel

1.5 kA

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL

125 °C (257 °F)

Fast

0219.630MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

4.82 J

-55 °C (-67 °F)

150 A

4.82

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, UL, VDE

125 °C (257 °F)

Time Lag

20106300301P

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

809 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

50E-1C-2.75S

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

50 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 10.875 in (76.2 x 276.23 mm)

10.875 in (276.23 mm)

Medium

LA070URD30TTI0160

Littelfuse

Electric Fuse

Inline/Holder

700 V

160 A

End Cap

1.6 J

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.929 in (40 x 40 x 49 mm)

1.929 in (49 mm)

UL

Very Fast

CY10X38M10

Littelfuse

Electric Fuse

Inline/Holder

500 V

10 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

0313004.HXIDP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

76.1 J

-55 °C (-67 °F)

Tin

200 A

Bulk

0.25 in (6.35 mm)

e3

Indicator

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL; KTL; PSE

125 °C (257 °F)

Time Lag

FLA10

Littelfuse

Electric Fuse

Inline/Holder

125 V

10 A

End Cap

10 kA

0.406 in (10.31 mm)

Indicator

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

UL

Slow

KLKR020.

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

BLF5

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

LMF3/10

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 mA

End Cap

10 kA

0.61 in (15.49 mm)

0.61 x 1.82 in (15.49 x 46.23 mm)

1.82 in (46.23 mm)

CSA; UL

Time Delay

CY14X51G32

Littelfuse

Electric Fuse

Inline/Holder

500 V

32 A

End Cap

120 kA

0.551 in (14 mm)

500 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Fast

L60S005

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

End Cap

-55 °C (-67 °F)

200 kA

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LCZ150ES

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

150 A

End Cap

80 kA

LCZ

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 17.87 in (162.05 x 453.89 mm)

17.87 in (453.89 mm)

Medium

KLKD8

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

8 A

End Cap

130.266 J

-55 °C (-67 °F)

100 kA

541 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

945 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

CCMR007.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

7 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 250 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0JLS025.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

25 A

End Cap

200 kA

0.811 in (20.6 mm)

J

600 V

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; QPL; UL

Fast

021901.6MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

44.2 J

-55 °C (-67 °F)

150 A

44.2

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, PSE, UL, VDE

125 °C (257 °F)

Time Lag

326.100P

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

87 mJ

Tin

100 A

326

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

Slow

235.800P

Littelfuse

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

253 mJ

-55 °C (-67 °F)

Tin

35 A

235P

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; UL

125 °C (257 °F)

Fast

SPFI012.L

Littelfuse

Electric Fuse

Inline/Holder

1 KV

12 A

End Cap

642 J

20 kA

4 m

642

Bulk

0.406 in (10.31 mm)

0.406 x 2.5 in (10.31 x 63.5 mm)

2.5 in (63.5 mm)

CE, TUV, UL

0322012.HXP

Littelfuse

Electric Fuse

Inline/Holder

65 V

65 V

12 A

End Cap

38 J

-55 °C (-67 °F)

Nickel

200 A

1 s

Rated Breaking Capacity at 65 VDC: 1000 A

60

Bulk

0.25 in (6.35 mm)

65 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Very Fast

LLSRK2.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

15E1C15.5

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

15 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 18.875 in (76.2 x 479.43 mm)

18.875 in (479.43 mm)

Medium

10E1C8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

10 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 15.875 in (76.2 x 403.23 mm)

15.874 in (403.2 mm)

Medium

TLS050

Littelfuse

Electric Fuse

Inline/Holder

170 V

50 A

End Cap

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

UL

LMF8

Littelfuse

Electric Fuse

Inline/Holder

300 V

8 A

End Cap

10 kA

0.61 in (15.49 mm)

0.61 x 1.82 in (15.49 x 46.23 mm)

1.82 in (46.23 mm)

CSA; UL

Time Delay

CY14X51M2

Littelfuse

Electric Fuse

Inline/Holder

690 V

2 A

End Cap

80 kA

0.551 in (14 mm)

690 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Time Lag

326.200

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

213 mJ

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA

Slow

KLDR005.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

40E-1C-15.5L

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

40 A

End Cap

60 kA

40E-1C-15.5

3 in (76.2 mm)

3 x 18.874 in (76.2 x 479.4 mm)

18.874 in (479.4 mm)

LCX200ES

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

200 A

End Cap

80 kA

LCX

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 10.875 in (162.05 x 276.23 mm)

10.875 in (276.23 mm)

Medium

500E-3C-5.5L

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

500 A

End Cap

80 kA

500E-3C-5.5

9.748 in (247.6 mm)

9.748 x 15.874 in (247.6 x 403.2 mm)

15.874 in (403.2 mm)

FLQ006

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0301001.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

1AG

0.625 in (15.87 mm)

Normal

313004PID

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

76.1 J

200 A

313P

0.25 in (6.35 mm)

Indicator

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; METI; PSE; UL

Slow

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.