End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0215005.MX

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

66.095 J

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.205 in (5.2 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CE; CSA; CUL; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

KLDR4/10

Littelfuse

Electric Fuse

400 mA

End Cap

200 kA

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Lag

RLN006

Littelfuse

Electric Fuse

Inline/Holder

250 V

6 A

End Cap

10 kA

0.563 in (14.3 mm)

2 in (50.8 mm)

CE; CSA; UL

100E-1C-2.75L

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

100 A

End Cap

80 kA

100E-1C-2.75

3 in (76.2 mm)

3 x 10.874 in (76.2 x 276.2 mm)

10.874 in (276.2 mm)

IDSR1.25T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

314010

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

206 J

-55 °C (-67 °F)

Tin

750 A

4 h

206

0.25 in (6.35 mm)

Supplemental

e3

250 V

10.5 mΩ

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; METI; PSE; QPL; UL

125 °C (257 °F)

Fast

L60S15

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

200 kA

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Fast

216002.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

1.87 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

216P

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Fast

151.5162.4806

Littelfuse

Electric Fuse

Inline/Holder

36 V

8 A

End Cap

151

Bulk

0.984 in (25 mm)

0.197 in (5 mm)

0.984 x 0.197 x 0.236 in (25 x 5 x 6 mm)

0.236 in (6 mm)

21801.6

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

10.331 J

-55 °C (-67 °F)

Tin

35 A

20 ms

Pre Arcing Time: Open within 20 ms at 1000% Rated Current

23.35

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

048103.5HMP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

3.5 A

End Cap

10.5 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0326.125HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

125 mA

End Cap

100 mJ

-55 °C (-67 °F)

Nickel

100 A

4 h

0.1

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

LA15QS2500-128

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

2.5 kA

End Cap

3.2 kJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

3 in (76.2 mm)

3 x 1.63 in (76.2 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

21606.3XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

57.9 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

216

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL

125 °C (257 °F)

Fast

LA60X700-128

Littelfuse

Electric Fuse

Inline/Holder

600 V

700 A

End Cap

100 kA

3 in (76.2 mm)

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

UL

Fast

0326.200MXCCP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

200 mA

End Cap

-55 °C (-67 °F)

4 h

0.213

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

FLQ1.12T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.12 A

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

AGW20CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

20 A

End Cap

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.225 mm)

SPFI002.L

Littelfuse

Electric Fuse

Inline/Holder

1 KV

2 A

End Cap

5 J

20 kA

4 m

5

Bulk

0.406 in (10.31 mm)

0.406 x 2.5 in (10.31 x 63.5 mm)

2.5 in (63.5 mm)

CE, TUV, UL

021301.6MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

44.2 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

44.2

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

15NLE-80ES

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

80 A

End Cap

60 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

03321.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

204 mJ

-55 °C (-67 °F)

100 A

200 ms

Rated Breaking Capacity at 125 VDC: 100 A

0.156

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CUL; PSE; UL

125 °C (257 °F)

Very Fast

1950400002

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

2.4 J

-25 °C (-13 °F)

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CCCE; CUL; IMQ; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

R452.750

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

750 mA

End Cap

904 mJ

-55 °C (-67 °F)

Tin/Lead

50 A

452

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e0

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; UL

125 °C (257 °F)

Slow

0312035.MXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

35 A

End Cap

7.531 kJ

-55 °C (-67 °F)

Matte Tin

300 A

20 s

Tape And Reel

0.25 in (6.35 mm)

e3

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

125 °C (257 °F)

Fast

0225008.MXUP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

8 A

End Cap

56 J

-55 °C (-67 °F)

Tin

500 A

4 h

56

Bulk

0.177 in (4.5 mm)

e3

125 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Fast

RLN035

Littelfuse

Electric Fuse

Inline/Holder

250 V

35 A

End Cap

10 kA

0.811 in (20.6 mm)

3 in (76.2 mm)

CE; CSA; UL

3561160002

Littelfuse

Electric Fuse

Inline/Holder

440 V

1.6 A

End Cap

8.3 J

-25 °C (-13 °F)

Nickel

1 kA

8.3

Bulk

0.248 in (6.3 mm)

Supplemental

440 V

147 mΩ

10 ms

3AB

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

UL

70 °C (158 °F)

Time Lag

0217.160MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

10 mJ

-55 °C (-67 °F)

35 A

10 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

215008

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

209.5 J

-55 °C (-67 °F)

Nickel

1.5 kA

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KTL; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

KLA60

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

60 A

End Cap

100 kA

KLA

Rated Breaking Capacity at 150 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 2 in (20.6 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Fast

0232004.

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

38.75 J

-55 °C (-67 °F)

Nickel

100 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

KTL; METI; PSE

125 °C (257 °F)

Medium

313001

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1 A

End Cap

14 J

-55 °C (-67 °F)

Tin/Lead

35 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

14

0.25 in (6.35 mm)

e0

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

125 °C (257 °F)

Slow

AGW6

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

6 A

End Cap

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.225 mm)

AGA6

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

6 A

End Cap

0.25 in (6.35 mm)

32 V

1AG

0.625 in (15.875 mm)

0213001.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

19.2 J

-55 °C (-67 °F)

Matte Tin

35 A

19.3

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

FLA2-1/2

Littelfuse

Electric Fuse

Inline/Holder

125 V

2.5 A

End Cap

10 kA

0.406 in (10.31 mm)

Indicator

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

UL

Slow

0219.063MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

28.5 mJ

-55 °C (-67 °F)

150 A

0.0285

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE, UL

125 °C (257 °F)

Time Lag

216.250XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

9.2 mJ

-55 °C (-67 °F)

Matte Tin

1.5 kA

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL

125 °C (257 °F)

Fast

0FLQ.150HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

150 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JTD10ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

1.69 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

L13S7

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

7 A

End Cap

100 kA

L13S

Rated Breaking Capacity at 150 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

JTD04.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

L60S17-1/2

Littelfuse

Electric Fuse

Inline/Holder

600 V

17.5 A

End Cap

200 kA

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Fast

FLSR1.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

216.630P

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

179 mJ

-55 °C (-67 °F)

Matte Tin

1.5 kA

216P

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

326.500

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

2.5 J

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Slow

F03B250V1/2AS

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

Silver

35 A

0.25 in (6.35 mm)

e4

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

MIL-PRF-15160/3

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.