End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

SPXI008.TXB

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

8 A

End Cap

121 J

30 kA

4 m

Bulk

0.406 in (10.31 mm)

4.49 in (114.05 mm)

TUV; UL

21501.6

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

3.798 J

-55 °C (-67 °F)

Nickel

1.5 kA

3.9

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

SPF0020

Littelfuse

Electric Fuse

Inline/Holder

1 KV

20 A

End Cap

20 kA

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

UL

LLNRK01.6

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

FLQ7

Littelfuse

Electric Fuse

Inline/Holder

500 V

7 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

JTD4ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

NLN008

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

8 A

End Cap

50 kA

Rated Breaking Capacity at 250 VDC; 20000

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

CY14X51M40

Littelfuse

Electric Fuse

Inline/Holder

500 V

40 A

End Cap

120 kA

0.551 in (14 mm)

500 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Time Lag

594003S

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

3 A

End Cap

Silver

594

e4

0229004.P

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

4 A

End Cap

148 J

-55 °C (-67 °F)

Nickel

400 A

0.177 in (4.5 mm)

Indicator

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

KLKD006.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

35 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

LA15QS20-2

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

20 A

End Cap

72 mJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

SPXC004.HXR

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

4 A

End Cap

56 J

15 kA

4 m

Bulk

0.406 in (10.31 mm)

0.394 x 2.244 in (10 x 57 mm)

2.252 in (57.2 mm)

CE; UL

Fast

2010125002

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

33 mJ

-25 °C (-13 °F)

Matte Tin

80 A

Bulk

0.205 in (5.2 mm)

e3

5 ms

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

DIN 41571; UL

70 °C (158 °F)

Medium Time Lag

0688005.MX

Littelfuse

Electric Fuse

5 A

End Cap

118 J

-55 °C (-67 °F)

Tin

2.5 kA

4 h

0.248 in (6.3 mm)

e3

700 V

0.248 x 0.992 in (6.3 x 25.2 mm)

0.992 in (25.2 mm)

UL

125 °C (257 °F)

02181.25TXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

12.65 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

12.65

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

AGC15CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

15 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

028502.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

25.625 J

-55 °C (-67 °F)

Gold

1.5 kA

10 ms

Bulk

0.205 in (5.2 mm)

e4

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE

125 °C (257 °F)

LA120URD71TTI0550

Littelfuse

Electric Fuse

Inline/Holder

1.2 KV

550 A

End Cap

84 J

100 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

FLSR.300ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

0481010H

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

10 A

End Cap

115.3 J

-55 °C (-67 °F)

Tin Lead

300 A

10 m

Rated Breaking Capacity at 125 VDC: 200 A

115.3

Bulk

0.665 in (16.9 mm)

0.23 in (5.84 mm)

e0

125 V

8.4 mΩ

Alarm

0.665 x 0.23 x 0.772 in (16.9 x 5.84 x 19.6 mm)

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

Fast

KLDR.300T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

300 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

1206SFS700F/24

Littelfuse

Electric Fuse

Surface Mount

24 V

7 A

End Cap

10 J

-55 °C (-67 °F)

Tin Over Nickel

60 A

Rated Breaking Capacity at 24 VDC: 60 A

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

Slow

FLNR1ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1 A

End Cap

200 kA

0.563 in (14.3 mm)

Indicator

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

0313002.IDHXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

77 J

-55 °C (-67 °F)

Tin

100 A

Bulk

0.25 in (6.35 mm)

e3

Indicator

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

20108000021P

Littelfuse

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

1.1 J

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

SPXV010.TXS

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

10 A

End Cap

407 J

Silver

30 kA

4 m

Bulk

0.406 in (10.31 mm)

e4

3.333 in (84.65 mm)

CE; CUL; IEC; UL

Fast

021802.5MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

23.25 J

-55 °C (-67 °F)

Tin

35 A

Bulk

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

02183.15MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

38.15 J

-55 °C (-67 °F)

Nickel

35 A

38.15

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0239.300MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

300 mA

End Cap

615 mJ

-55 °C (-67 °F)

Tin

35 A

4 h

0.6

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; UL

125 °C (257 °F)

Time Lag

FLQ02.5

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2.5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

021301.6P

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

44.2 J

-55 °C (-67 °F)

Nickel

35 A

213P

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

LA130URD73TTI0315

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

315 A

End Cap

12 J

100 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

02351.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

1.085 J

-55 °C (-67 °F)

Nickel

100 A

5 s

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 x 0.205 in (20 x 5.2 mm)

0.787 in (20 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

CY14X51M16

Littelfuse

Electric Fuse

Inline/Holder

690 V

16 A

End Cap

80 kA

0.551 in (14 mm)

690 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Time Lag

BLF01.5

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.5 A

End Cap

10 kA

2 m

Bulk

0.406 in (10.31 mm)

250 V

5AG

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Fast

215.200XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

370 mJ

-55 °C (-67 °F)

Tin

1.5 kA

215

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; SEV; SEMKO; UL

125 °C (257 °F)

Time Lag

1951200002

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

10 J

-25 °C (-13 °F)

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CCCE; CUL; IMQ; MITI; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

239.250P

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

341 mJ

-55 °C (-67 °F)

Matte Tin

35 A

239P

Bulk; Tape And Reel

0.787 in (20 mm)

e3

0.787 x 0.205 in (20 x 5.2 mm)

0.205 in (5.2 mm)

CE; CSA; KTL; UL

125 °C (257 °F)

Time Lag

0314.375HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

375 mA

End Cap

50 mJ

-55 °C (-67 °F)

Nickel

35 A

Rated Breaking Capacity at 125 VDC: 10000 A

0.05

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Fast

FLQ41/2

Littelfuse

Electric Fuse

Inline/Holder

500 V

4.5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

5NLE-200ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

200 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

JTD01.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

0213.800MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

9.42 J

-55 °C (-67 °F)

35 A

9.42

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, UL, VDE

125 °C (257 °F)

Time Lag

218010.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

567.696 J

-55 °C (-67 °F)

Matte Tin

100 A

30 m

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

250 V

4.5 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KTL; PSE; UL; VDE

125 °C (257 °F)

Time Lag

25E-1C-25.8L

Littelfuse

Electric Fuse

Inline/Holder

25.8 KV

25 A

End Cap

40 kA

25E-1C-25.8

3 in (76.2 mm)

3 x 24.626 in (76.2 x 625.5 mm)

24.626 in (625.5 mm)

0481.200VP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

200 mA

End Cap

14 mJ

-55 °C (-67 °F)

300 A

5 m

Bulk

0.701 in (17.8 mm)

0.209 in (5.3 mm)

Alarm

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

125E2C2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

125 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 10.875 in (162.05 x 276.23 mm)

10.874 in (276.2 mm)

Medium

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.