End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

200E-2C-2.75L

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

200 A

End Cap

80 kA

200E-2C-2.75

6.378 in (162 mm)

6.378 x 10.874 in (162 x 276.2 mm)

10.874 in (276.2 mm)

15E-1C-2.75L

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

15 A

End Cap

80 kA

15E-1C-2.75

3 in (76.2 mm)

3 x 10.874 in (76.2 x 276.2 mm)

10.874 in (276.2 mm)

R271.750

Littelfuse

Electric Fuse

Surface Mount

60 V

60 V

750 mA

End Cap

155 mJ

-55 °C (-67 °F)

50 A

1 s

Rated Breaking Capacity at 60 VDC: 300 A, Pre Arcing Time: Open within 1 s at 200% Rated Current

Tape And Reel

0.08 in (2.032 mm)

Nano

0.225 in (5.715 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L25S6

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Fast

225.100MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

750 μJ

Tin

35 A

225

Bulk

0.177 in (4.5 mm)

e3

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; UL

Fast

0215.630HX

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

635 mJ

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.205 in (5.2 mm)

e3

250 V

5 µs

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CE; CSA; CUL; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

200-9R-1C-5.5XW

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

200 A

End Cap

760 A

Part Number With Hookeye Attachment

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

0313005.HXIDP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

140 J

-55 °C (-67 °F)

Tin

200 A

Bulk

0.25 in (6.35 mm)

e3

Indicator

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL; KTL; PSE

125 °C (257 °F)

Time Lag

0481.250HXLM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

250 mA

End Cap

62.5 mJ

-55 °C (-67 °F)

40 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

1810630002

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

770 mJ

-40 °C (-40 °F)

1.5 kA

Bulk

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CNCA; CUL; IEC; UL

85 °C (185 °F)

Time Lag

0688010.MXP

Littelfuse

Electric Fuse

Inline/Holder

70 V

10 A

End Cap

570 J

-55 °C (-67 °F)

Tin

2.5 kA

2 m

Bulk

0.248 in (6.3 mm)

e3

0.236 x 0.984 in (6 x 25 mm)

0.992 in (25.2 mm)

CUL; UL

125 °C (257 °F)

Time Delay

0235.125HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

2.73 mJ

-55 °C (-67 °F)

Nickel

35 A

5 s

Bulk

0.197 in (5 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA, CE, UL

125 °C (257 °F)

Fast

0303002.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

2 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.22 mm)

Normal

0448.160NR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

160 mA

End Cap

2.8 mJ

-55 °C (-67 °F)

Gold

50 A

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; PSE; UL

125 °C (257 °F)

Very Fast

225007

Littelfuse

Electric Fuse

Inline/Holder

125 V

7 A

End Cap

40 J

10 kA

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

3260.15MMXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

150 mA

End Cap

143 mJ

-55 °C (-67 °F)

Matte Tin

100 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

031201.6VX

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

2.8 J

-55 °C (-67 °F)

Tin

100 A

312

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

1930100000

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

7 mJ

-25 °C (-13 °F)

35 A

3 ms

Bulk

0.205 in (5.2 mm)

250 V

3 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; DIN; IEC; SEMKO; UL; VDE

70 °C (158 °F)

Very Fast

15NLE30E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

30 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

04653.15

Littelfuse

Electric Fuse

Surface Mount

250 V

3.15 A

End Cap

31.7 J

-55 °C (-67 °F)

Silver

100 A

Joule Integral Nom at Rated Voltage(DC): 31.7

31.7

Tape And Reel

0.476 in (12.1 mm)

0.177 in (4.5 mm)

e4

250 V

21 mΩ

Nano

0.476 x 0.177 x 0.177 in (12.1 x 4.5 x 4.5 mm)

0.177 in (4.5 mm)

METI; PSE; UL

125 °C (257 °F)

Time Lag

0229006.MXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

6 A

End Cap

380 J

-55 °C (-67 °F)

Tin

400 A

3 s

380

Bulk

0.189 in (4.8 mm)

e3

125 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

LCX10E

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

10 A

End Cap

80 kA

LCX

3 in (76.2 mm)

3 x 10.875 in (76.2 x 276.23 mm)

10.875 in (276.23 mm)

Medium

LGR8

Littelfuse

Electric Fuse

Inline/Holder

300 V

8 A

End Cap

10 kA

0.61 in (15.49 mm)

0.61 x 1.82 in (15.49 x 46.23 mm)

1.82 in (46.23 mm)

CSA; UL

Fast

KLKD001.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

8 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

CCMR020.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

20 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

239.750P

Littelfuse

Electric Fuse

Inline/Holder

250 V

750 mA

End Cap

5.424 J

-55 °C (-67 °F)

Matte Tin

35 A

239P

Bulk; Tape And Reel

0.787 in (20 mm)

e3

0.787 x 0.205 in (20 x 5.2 mm)

0.205 in (5.2 mm)

CE; CSA; KTL; UL

125 °C (257 °F)

Time Lag

TOO5.60

Littelfuse

Electric Fuse

Inline/Holder

125 V

5.6 A

End Cap

10 kA

UL

Time Delay

0313020.HXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

20 A

End Cap

9.56 kJ

-55 °C (-67 °F)

Matte Tin

300 A

4 h

9560

Bulk

0.25 in (6.35 mm)

Supplemental

e3

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

UL

125 °C (257 °F)

Time Lag

7945816041

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

LA070URD31TTI0550

Littelfuse

Electric Fuse

Inline/Holder

700 V

550 A

End Cap

52 J

200 kA

2 in (50.8 mm)

2 in (50.8 mm)

Indicator

2 x 2 x 1.929 in (50.8 x 50.8 x 49 mm)

1.929 in (49 mm)

UL

Very Fast

1980125000

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

66 mJ

-25 °C (-13 °F)

35 A

Bulk

0.205 in (5.2 mm)

5 s

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA; UL

70 °C (158 °F)

Time Delay

21301.6XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

44.2 J

-55 °C (-67 °F)

Matte Tin

100 A

213

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

0481.200VM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

200 mA

End Cap

57.6 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

3264MMXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

9.71 J

-55 °C (-67 °F)

Matte Tin

400 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

07945810195

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

750 mA

End Cap

234 mJ

-55 °C (-67 °F)

100 kA

63 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

170 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

0208005.DRT1

Littelfuse

Electric Fuse

5 A

End Cap

17 J

-55 °C (-67 °F)

100 A

Tape And Reel

0.189 in (4.8 mm)

350 V

2AG

0.189 x 0.587 in (4.8 x 14.9 mm)

0.587 in (14.9 mm)

CE, PSE, UL

125 °C (257 °F)

Fast

0FLQ.200HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

200 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0977004.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

4 A

End Cap

124 J

-55 °C (-67 °F)

100 A

Rated Breaking Capacity at 450 VDC: 200 A, Pre-Arcing Time: Open within 10 ms at 1000% Rated Current

124

Bulk

0.205 in (5.2 mm)

500 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE; SEMKO

125 °C (257 °F)

Time Lag

04810180HXL

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

8.08 mJ

-55 °C (-67 °F)

300 A

5 m

Bulk

0.839 in (21.3 mm)

0.228 in (5.8 mm)

Alarm

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

1960032000

Littelfuse

Electric Fuse

Inline/Holder

250 V

32 mA

End Cap

10 mJ

-25 °C (-13 °F)

150 A

Bulk

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CUL; IEC; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

151.5155.4502

Littelfuse

Electric Fuse

Inline/Holder

36 V

5 A

End Cap

Bulk

0.984 in (25 mm)

0.197 in (5 mm)

0.197 x 0.984 in (5 x 25 mm)

0.236 in (6 mm)

021302.5MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

138 J

-55 °C (-67 °F)

35 A

138

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, PSE, UL, VDE

125 °C (257 °F)

Time Lag

3260.125MVXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

100 mJ

-55 °C (-67 °F)

Matte Tin

100 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

1810160000

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

35 mJ

-40 °C (-40 °F)

1.5 kA

181

Bulk

0.205 in (5.2 mm)

10 ms

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CNCA; CUL; IEC; UL

85 °C (185 °F)

Time Lag

LLNRK1.12

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1.125 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

0215.315MXB

Littelfuse

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

975 mJ

-55 °C (-67 °F)

1.5 kA

0.975

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Time Lag

LA70QS20-14FI

Littelfuse

Electric Fuse

Inline/Holder

690 V

700 V

20 A

End Cap

160 mJ

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CSA; UL

Very Fast

32620MVXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

60 V

20 A

End Cap

575 J

-55 °C (-67 °F)

Matte Tin

400 A

Rated Breaking Capacity at 60 VDC: 500 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.