Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

2011125000

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

3.2 J

-25 °C (-13 °F)

Matte Tin

80 A

Bulk

0.205 in (5.2 mm)

e3

5 ms

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

DIN 41571; UL

70 °C (158 °F)

Medium Time Lag

0FLQ2.25T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

2.25 A

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

218.160

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

219 mJ

-55 °C (-67 °F)

Tin

35 A

20 ms

Pre Arcing Time: Open within 20 ms at 1000% Rated Current

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; SEMKO; UL

125 °C (257 °F)

Time Lag

0235.600MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

600 mA

End Cap

112 mJ

-55 °C (-67 °F)

35 A

5 s

Bulk

0.197 in (5 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA, CE, UL

125 °C (257 °F)

Fast

L13S30

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

30 A

End Cap

100 kA

L13S

Rated Breaking Capacity at 150 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0326.375MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

375 mA

End Cap

1.2 J

-55 °C (-67 °F)

Nickel

100 A

5 s

Rated Breaking Capacity at 125 VDC: 10000 A

1.2

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Delay

LA130URD71TTI0200

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

200 A

End Cap

4.7 J

100 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

JLLS001

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 1.5 in (14.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

1206SFS450FM/32

Littelfuse

Electric Fuse

Surface Mount

32 V

4.5 A

End Cap

-55 °C (-67 °F)

Tin Over Nickel

Rated Breaking Capacity at 32 VDC: 50 A

0.134 in (3.4 mm)

0.071 in (1.8 mm)

e3

0.134 x 0.071 x 0.046 in (3.4 x 1.8 x 1.17 mm)

0.046 in (1.17 mm)

UL

125 °C (257 °F)

Slow

0217008.MXGP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

198.16 J

-55 °C (-67 °F)

80 A

10 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CE; IEC; KC; PSE; VDE; UL

125 °C (257 °F)

Very Fast

0481010.VXLP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

10 A

End Cap

380.3 J

-55 °C (-67 °F)

Tin

300 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

3260.375MHXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

375 mA

End Cap

1.2 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

2410500002

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.5 J

-25 °C (-13 °F)

Nickel

80 A

Bulk

0.205 in (5.2 mm)

250 V

5 ms

0.197 x 0.984 in (5 x 25 mm)

Indicator

0.205 x 0.984 in (5.2 x 25 mm)

0.984 in (25 mm)

70 °C (158 °F)

Medium Time Lag

LA15QS4000-128

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

4 kA

End Cap

8.5 kJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

3.5 in (88.9 mm)

3.5 x 1.63 in (88.9 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

15NLE2-80EL

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

80 A

End Cap

60 kA

15NLE2-80E

6.378 in (162 mm)

6.378 x 23.874 in (162 x 606.4 mm)

23.874 in (606.4 mm)

SPXV006.L

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

6 A

End Cap

49 J

Nickel

30 kA

4 m

Bulk

0.406 in (10.31 mm)

GPV

1.5 KV

0.394 x 3.346 in (10 x 85 mm)

0.409 x 3.358 in (10.4 x 85.3 mm)

3.333 in (84.65 mm)

CUL; TUV; UL

Fast

0314040.VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

150 V

40 A

End Cap

22.925 kJ

-55 °C (-67 °F)

Nickel

1 kA

Rated Breaking Capacity at 150 VDC: 400 A

22925

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; UL

125 °C (257 °F)

Fast

2173.15P

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

17.722 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Fast

FLQ.125

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

125 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

314025.MX280P

Littelfuse

Electric Fuse

Inline/Holder

280 V

25 A

End Cap

50 A

314P

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

Fast

23902.5

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

79.701 J

-55 °C (-67 °F)

Tin/Lead

100 A

4 h

79.705

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

e0

250 V

58.4 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

225008P

Littelfuse

Electric Fuse

Inline/Holder

125 V

8 A

End Cap

56 J

Tin

500 A

225

Bulk

0.177 in (4.5 mm)

e3

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; UL

Fast

70X

Littelfuse

Electric Fuse

Inline/Holder

125 V

300 V

200 mA

End Cap

1 kA

70

Rated Breaking Capacity at 300 VDC: 1000 A

Alarm

UL

217.050P

Littelfuse

Electric Fuse

Inline/Holder

250 V

50 mA

End Cap

190 μJ

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; SEMKO; UL; VDE

125 °C (257 °F)

Fast

1911400000

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

40 J

-25 °C (-13 °F)

10 kA

Bulk

0.205 in (5.2 mm)

5 s

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Very Fast

0313.700VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

700 mA

End Cap

5.9 J

-55 °C (-67 °F)

Nickel

35 A

313

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

218001

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

3.33 J

-55 °C (-67 °F)

35 A

20 ms

Pre Arcing Time: Open within 20 ms at 1000% Rated Current

6.73

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; SEV; UL

125 °C (257 °F)

Time Lag

31201.8

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

1.8 A

End Cap

3.85 J

35 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

KLDR002

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

861.5 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

2131.25

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.25 A

End Cap

27.15 J

-55 °C (-67 °F)

Nickel

100 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

KLK25

Littelfuse

Electric Fuse

Inline/Holder

600 V

25 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

125E1C5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

125 A

End Cap

80 kA

10 m

3 in (76.2 mm)

Striker

3 x 15.875 in (76.2 x 403.23 mm)

15.874 in (403.2 mm)

Medium

020902.5DRT1P

Littelfuse

Electric Fuse

Inline/Holder

350 V

2.5 A

End Cap

-55 °C (-67 °F)

Tin

100 A

4 h

50

Tape And Reel

0.177 in (4.5 mm)

e3

350 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE, PSE, UL

125 °C (257 °F)

Time Lag

1960800000

Littelfuse

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

11 J

-25 °C (-13 °F)

150 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CUL; IEC; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

0217.315HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

110 mJ

-55 °C (-67 °F)

Tin

35 A

10 ms

Bulk

0.205 in (5.2 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

KLDR6.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.25 A

End Cap

147.6 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

BLN8

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

LCY150ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

150 A

End Cap

80 kA

LCY

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

0216.160P

Littelfuse

Electric Fuse

Inline/Holder

250 V

160 mA

End Cap

5.76 mJ

-55 °C (-67 °F)

Matte Tin

1.5 kA

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0219.400MXAP

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

1.4 J

-55 °C (-67 °F)

Nickel

150 A

20 ms

1.4

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Time Lag

0285008HXRP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

224 J

-55 °C (-67 °F)

1.5 kA

10 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

PSE

125 °C (257 °F)

KLNR008

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

8 A

End Cap

200 kA

KLNR

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

2 in (50.8 mm)

CSA; UL

Fast

FLM.500

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

500 mA

End Cap

10 kA

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

250 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

NLS010

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

10 A

End Cap

50 kA

Rated Breaking Capacity at 500 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

0312002.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

5.2 J

-55 °C (-67 °F)

Tin

100 A

312

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

175E-2C-2.75S

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

175 A

End Cap

80 kA

175E-2C-2.75

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 10.875 in (162.05 x 276.23 mm)

10.875 in (276.23 mm)

Medium

LCX40ES

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

40 A

End Cap

80 kA

LCX

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 10.875 in (76.2 x 276.23 mm)

10.875 in (276.23 mm)

Medium

021901.6

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

10.61 J

150 A

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CSA; IEC; KTL; METI; PSE; SEMKO; UL; VDE

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.