End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

CY10X38M1

Littelfuse

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

594030

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

30 A

End Cap

Nickel

594

0229001.S

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

35 A

229

Joule Integral Nom at Rated Volatge(DC): 5.64

Indicator

CSA; PSE; UL

Slow

CCMR.600TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0239.750P

Littelfuse

Electric Fuse

Inline/Holder

125 V

750 mA

End Cap

5.425 J

-55 °C (-67 °F)

Nickel

35 A

239

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; UL

125 °C (257 °F)

Time Lag

218001M

Littelfuse

Electric Fuse

1 A

End Cap

-55 °C (-67 °F)

35 A

6.73

0.787 in (20 mm)

Supplemental

250 V

61.3 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; PSE; UL; VDE

125 °C (257 °F)

Time Lag

0452005.

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

5 A

End Cap

53.72 J

-55 °C (-67 °F)

Tin Lead

50 A

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.106 in (2.69 mm)

0.106 in (2.69 mm)

e0

0.106 x 0.106 x 0.24 in (2.69 x 2.69 x 6.1 mm)

0.24 in (6.1 mm)

CSA; METI; PSE; UL

125 °C (257 °F)

Fast

3401800002

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

150 J

-25 °C (-13 °F)

200 A

Bulk

0.248 in (6.3 mm)

120 s

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CSA; UL

70 °C (158 °F)

Very Fast

FLQ15/100

Littelfuse

Electric Fuse

Inline/Holder

500 V

150 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

FLM20

Littelfuse

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

0.406 in (10.31 mm)

250 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Slow

0312.200HX

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

16.5 mJ

-55 °C (-67 °F)

Tin

35 A

312

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Fast

0452.375L

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

375 mA

End Cap

101 mJ

-55 °C (-67 °F)

Gold

50 A

452

Rated Breaking Capacity at 125 VDC: 50

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; UL

125 °C (257 °F)

Slow

216.063PV

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

540 μJ

-55 °C (-67 °F)

Matte Tin

1.5 kA

216P

Bulk

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

LA15QS3000-128IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

3 kA

End Cap

4.8 kJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

3 in (76.2 mm)

3 x 1.63 in (76.2 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

TLS-LS006

Littelfuse

Electric Fuse

Inline/Holder

170 V

6 A

End Cap

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.562 in (14.27 mm)

e4

0.562 x 0.944 in (14.27 x 23.98 mm)

0.944 in (23.98 mm)

UL

SPXV005.TXS

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

5 A

End Cap

48 J

30 kA

4 m

Bulk

0.406 in (10.31 mm)

3.333 in (84.65 mm)

CE; CUL; IEC; UL

Fast

0209005MXP

Littelfuse

Electric Fuse

Inline/Holder

350 V

5 A

End Cap

267 J

-55 °C (-67 °F)

Tin

100 A

Bulk

0.177 in (4.5 mm)

e3

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; PSE; UL

125 °C (257 °F)

Time Lag

0239.100HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

55 mJ

-55 °C (-67 °F)

Tin

35 A

4 h

0.05

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; UL

125 °C (257 °F)

Time Lag

AGU2

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

2 A

End Cap

0.406 in (10.3187 mm)

32 V

5AG

1.5 in (38.1 mm)

KLNR050

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

50 A

End Cap

200 kA

KLNR

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

3 in (76.2 mm)

CSA; UL

Fast

CCMR17.5TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

17.5 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

313.300P

Littelfuse

Electric Fuse

Inline/Holder

250 V

300 mA

End Cap

730 mJ

Tin

35 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

0.25 in (6.35 mm)

e3

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

Slow

1811500000

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

77 J

-40 °C (-40 °F)

Tin

1.5 kA

181

Bulk

0.205 in (5.2 mm)

e3

20 ms

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CUL; IEC; METI; PSE; SEMKO; SEV; UL; VDE

85 °C (185 °F)

Time Lag

312.600P

Littelfuse

Electric Fuse

Inline/Holder

250 V

600 mA

End Cap

880 mJ

Nickel

35 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Fast

LLSRK02.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LA60X800-128

Littelfuse

Electric Fuse

Inline/Holder

600 V

800 A

End Cap

100 kA

3 in (76.2 mm)

600 V

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

UL

Fast

AGC1ZP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

Normal

0481004.VXLMP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

4 A

End Cap

36 J

-55 °C (-67 °F)

300 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

FLM31/2

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.5 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Slow

LDZ50ES

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

50 A

End Cap

80 kA

LDZ

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

1961250000

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

17 J

-25 °C (-13 °F)

150 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BSI; CUL; IEC; SEMKO; UL; VDE

70 °C (158 °F)

Time Lag

7945816073

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

30 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

FLNR.100

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

100 mA

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

0313.125VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

152 mJ

-55 °C (-67 °F)

Nickel

35 A

4 h

0.152

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

1980500002

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.6 J

-25 °C (-13 °F)

35 A

Bulk

0.205 in (5.2 mm)

5 s

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA; UL

70 °C (158 °F)

Time Delay

LLSRK2.80

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

20 kA

Rated Breaking Capacity at 300 VDC: 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

Time Delay

0481015.VXLP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

15 A

End Cap

900 J

-55 °C (-67 °F)

Tin

300 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

KLKD005.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

End Cap

24 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

LDZ300ES

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

300 A

End Cap

80 kA

LDZ

Hermitically Sealed Part Number

9.75 in (247.65 mm)

9.75 x 15.875 in (247.65 x 403.23 mm)

15.875 in (403.23 mm)

Medium

LA15QS1000-128IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

1 kA

End Cap

540 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

2 in (50.8 mm)

2 x 1.63 in (50.8 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

0SPF020.TXS

Littelfuse

Electric Fuse

Inline/Holder

1 KV

20 A

End Cap

1.313 kJ

Silver

20 kA

4 m

Bulk

0.406 in (10.31 mm)

e4

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

BLS7

Littelfuse

Electric Fuse

Inline/Holder

250 V

7 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.375 in (10.31 x 34.93 mm)

1.375 in (34.93 mm)

CSA; UL

Fast

3400150000

Littelfuse

Electric Fuse

Inline/Holder

250 V

150 mA

End Cap

4.4 mJ

-25 °C (-13 °F)

35 A

Bulk

0.248 in (6.3 mm)

120 s

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CSA; UL

70 °C (158 °F)

Very Fast

390-18R-2C-5.5XS

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

390 A

End Cap

1.5 kA

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 17.875 in (162.05 x 454.03 mm)

17.875 in (454.03 mm)

Medium

LGD080

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

Time Delay

0AGC002.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

2 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

229005M

Littelfuse

Electric Fuse

Inline/Holder

125 V

5 A

End Cap

267 J

-55 °C (-67 °F)

Tin/Lead

400 A

4 h

267

Bulk

0.177 in (4.5 mm)

e0

125 V

18.6 mΩ

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; METI; PSE; UL

125 °C (257 °F)

Slow

0KLK005.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

5 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.