End Cap Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

2E-4PT-2.4

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

3 A

End Cap

37 kA

0.813 in (20.64 mm)

0.813 x 4.6 in (20.64 x 116.84 mm)

4.6 in (116.84 mm)

Medium

59303.5

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

3.5 A

End Cap

Nickel

593

0FLQ.800T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

800 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0215.200MX

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

340 mJ

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.205 in (5.2 mm)

e3

250 V

5 µs

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CE; CUL; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

225008DRT1

Littelfuse

Electric Fuse

Inline/Holder

125 V

8 A

End Cap

56 J

10 kA

225

Tape And Reel

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

023302.5XP

Littelfuse

Electric Fuse

Inline/Holder

125 V

2.5 A

End Cap

17.5 J

-55 °C (-67 °F)

Nickel

10 kA

233

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Medium

NLN030

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

30 A

End Cap

50 kA

Rated Breaking Capacity at 250 VDC; 20000

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

JLLS001.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

0312007.P

Littelfuse

Electric Fuse

Inline/Holder

250 V

7 A

End Cap

118 J

-55 °C (-67 °F)

Tin

200 A

312

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

0216010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

154.34 J

-55 °C (-67 °F)

Nickel

1.5 kA

30 ms

154.34

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Fast

023206.3P

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

90.413 J

-55 °C (-67 °F)

Tin

100 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; PSE

125 °C (257 °F)

Medium

21306.3XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

600 J

-55 °C (-67 °F)

Matte Tin

100 A

213

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

322008P

Littelfuse

Electric Fuse

Inline/Holder

250 V

65 V

8 A

End Cap

100 A

322P

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

UL

Very Fast

40E-1C-5.5S

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

40 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

JTD01.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

SOO-0.25

Littelfuse

Electric Fuse

Inline/Holder

125 V

25 A

End Cap

10 kA

UL

Time Delay

1E-8PT-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

1 A

End Cap

50 kA

1.563 in (39.69 mm)

1.563 x 9.5 in (39.69 x 241.3 mm)

9.5 in (241.3 mm)

Medium

0481002.HXM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

2 A

End Cap

10.2 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0SLC004.T

Littelfuse

Electric Fuse

4 A

End Cap

100 kA

0.406 in (10.3 mm)

G

600 V

0.406 x 1.311 in (10.3 x 33.3 mm)

1.311 in (33.3 mm)

CSA, UL

Medium

0209004.DRT1P

Littelfuse

Electric Fuse

4 A

End Cap

-55 °C (-67 °F)

Tin

100 A

4 h

148

0.177 in (4.5 mm)

e3

350 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE, PSE, UL

125 °C (257 °F)

Time Lag

0313.300HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

300 mA

End Cap

730 mJ

-55 °C (-67 °F)

Nickel

35 A

4 h

0.73

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

SPXV004.T

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

4 A

End Cap

14 J

30 kA

4 m

Bulk

0.406 in (10.31 mm)

GPV

1.5 KV

0.394 x 3.346 in (10 x 85 mm)

3.333 in (84.65 mm)

CUL; TUV; UL

Fast

R452.500

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

500 mA

End Cap

240 mJ

-55 °C (-67 °F)

Tin/Lead

50 A

452

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e0

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; UL

125 °C (257 °F)

Slow

7945816032

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

1.125 A

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

0229.600HXSP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 mA

End Cap

1.75 J

-55 °C (-67 °F)

Matte Tin

35 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.177 in (4.5 mm)

e3

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

1981300002

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

110 J

-25 °C (-13 °F)

100 A

Bulk

0.205 in (5.2 mm)

5 s

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA; UL

70 °C (158 °F)

Time Delay

LCN100ESS

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

60 kA

LCN

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

0326.700HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

700 mA

End Cap

6.42 J

-55 °C (-67 °F)

Nickel

100 A

4 h

6.42

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0213.250

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

555 mJ

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL

125 °C (257 °F)

Time Lag

AGC1BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

AGA2H/301002

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

2 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

1AG

0.625 in (15.87 mm)

Normal

KLW30

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

30 A

End Cap

100 kA

KLW

Rated Breaking Capacity at 150 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0217.250HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

40 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

32620MHXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

60 V

20 A

End Cap

575 J

-55 °C (-67 °F)

Matte Tin

400 A

Rated Breaking Capacity at 60 VDC: 500 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

LDZ250E

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

250 A

End Cap

80 kA

LDZ

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

FLNR35ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

35 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 3 in (20.6 x 76.2 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

02010630FRT1L

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

600 mJ

-25 °C (-13 °F)

80 A

5 ms

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

0SPF03.5H

Littelfuse

Electric Fuse

Inline/Holder

1 KV

3.5 A

End Cap

11 J

Nickel

20 kA

4 m

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; TUV; UL

Fast

0216.063P

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

540 μJ

-55 °C (-67 °F)

Matte Tin

1.5 kA

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Fast

UK35BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

35 A

End Cap

0.25 in (6.35 mm)

32 V

1.25 in (31.75 mm)

0309625M

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

30 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

8AG

1 in (25.4 mm)

Normal

0219.800XAP

Littelfuse

Electric Fuse

Inline/Holder

250 V

800 mA

End Cap

9.35 J

-55 °C (-67 °F)

Nickel

150 A

219XAP

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CSA; IEC; SEMKO; VDE

125 °C (257 °F)

Time Lag

5NLE-100ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

100 A

End Cap

80 kA

Hermitically Sealed Part Number

3 in (76.2 mm)

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

KLDR.750T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

750 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

197-1400-000

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

32 J

-25 °C (-13 °F)

10 kA

Bulk

0.205 in (5.2 mm)

120 s

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

217002.

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

2 A

End Cap

5.726 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KTL; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0326.100HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

100 mA

End Cap

87 mJ

-55 °C (-67 °F)

Nickel

100 A

4 h

0.087

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Lag

KLQ005

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

600 V

Midget

0.406 x 1.375 in (10.31 x 34.93 mm)

1.375 in (34.93 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.